Qwest Spirit of Service
Qwest.com | About Qwest  
Products and Services Customer Service Manage My Account
 
Wholesale Contact Us
Products & Services Product Catalog (PCAT)

Product Catalog (PCAT)

Product Description

Pricing

Features/Benefits

Applications

Implementation
  Pre Ordering
  Ordering
  Provisioning
  Maintenance
  Billing
  Training

Contacts

FAQs

 

Facility Connected (FC) Collocation - V17.0

History Log

Product Description

Facility Connected (FC) Collocation allows you to access Unbundled Network Elements (UNEs), Ancillary Services and Finished Services within a Qwest Central Office (CO) using an entrance facility without collocating equipment in the CO. FC Collocation takes place on a termination block or termination panel within the designated CO and is engineered by Qwest; terminating a copper or fiber cable at a demarcation point for cross-connection to the desired service facilitates interconnection or access to UNEs, Ancillary Services, or Finished Services.

Product Diagram

FC Collocation Product Diagram

Availability

FC Collocation is available where facilities exist throughout Qwest's 14-state local service territory.

Terms and Conditions

Terms and conditions are included in your Interconnection Agreement, and if those terms differ from those set forth in this web, then the terms of your Interconnection Agreement may prevail.

Additional information regarding Collocation terms and conditions are located in the Terms and Conditions section of the Collocation - General Information.

Qwest performs the cross connection at the demarcation point based on information on the Alternate Point of Termination (APOT) form.

FC Collocation is available with the following configurations:

  • Copper Entrance Facility for termination and cross-connection to appropriate Digital Service Level 0 (DS0) and Digital Service Level 1 (DS1) UNE services.
      If the Copper Entrance facility is to be utilized for DS1 UNEs, you must provide two (2) CFA assignments and must transmit a Trunk Level 1 (T1) templated signal over the copper facility. DS1 Copper entrance facilities may be wired to a DS1 office repeater to remove line voltage before terminating on the Digital System Cross-Connect (DSX) panel. Qwest will install and charge for this repeater equipment.
  • Fiber Entrance Facility termination and cross-connection to appropriate fiber UNEs
  • Other levels of service such as DS1 or Digital Service Level 3 (DS3) with fiber are available using the Bona Fide Request (BFR) process.

All Qwest terminations on the Termination Frame or Termination Panel have a frame address. Qwest will establish and maintain frame or panel address records for Qwest terminations. You will be required to maintain your address records.

Protection from lightning or voltage is required for copper entrance facilities and require protection units on standard connector blocks on the distribution frame. Qwest will engineer and install this protection and bill you for these materials and labor as part of the FC Collocation request. All copper cables used for interconnection or access to UNEs, Ancillary Services, or Finished Services must come through a cable vault/entrance facility and have grounded/bonded sheaths.

You will be responsible for providing an entrance facility to Collocation - Point of Interconnection (C-POI).

Technical Publications
Qwest's Technical Publications with reference to Collocation are located in the Technical Publications section of Collocation - General Information.

Back to Top

Pricing

Rate Structure
Collocation rate elements are located in the Pricing section of Collocation - General Information.

FC Collocation charges are based on the information you provided on your Collocation Application form and the work to be preformed. There are additional charges that are unique to FC Collocation and typically could appear on a FC Collocation quote:

Recurring charges are comprised of the following rate elements:

  • Entrance Facility Charges
  • Termination Block or Termination Panel Charges

Nonrecurring charges are comprised of the following rate elements:

  • Engineering Charge
  • Entrance Facility Charges
  • Quote Preparation Fee (QPF)
  • Termination Block or Termination Panel Charges
Rates

Wholesale rates for this product or service, including tariff references and any applicable discounts, are provided in your current Interconnection, Resale, Commercial or other governing agreement.

Tariffs, Regulations and Policies

Tariffs, regulations and policies are located in the state specific Tariffs/Catalogs/Price Lists.

Optional Features

Optional features are located in the Optional Features section of Collocation - General Information

Back to Top

Features/Benefits

Features Benefits
Access to local services using FC Collocation.
  • Allows you to access UNEs, Ancillary Services and Finished Services without placing equipment in the CO.

Back to Top

Applications

Allows you to access UNEs, Ancillary Services and Finished Services without collocating in a CO.

Back to Top

Implementation

Product Prerequisites
If you are a new CLEC and are ready to do business with Qwest, view Getting Started as a Facility-Based CLEC. If you are an existing CLEC wishing to amend your Interconnection Agreement or New Customer Questionnaire, additional information is located in the Interconnection Agreement.

Back to Top

Pre-Ordering

General pre-ordering activities are described in the Pre-Ordering section of Collocation - General Information.

Back to Top

Ordering

General ordering activities are described in the Ordering section of Collocation - General Information.

To request FC Collocation in a particular Qwest CO use the FC Collocation Application form. Application and APOT(s) forms specific to Facility Connected Collocation can be found under Applications and APOT forms table in the Collocation - General Information.

Information on how to cancel a FC Collocation order already in progress is located in the Collocation - Cancellation Overview process. Collocation application forms can be found under Applications and APOT forms table in the Collocation - General Information.

Information on how to decommission a completed FC Collocation site is in the Remote/Adjacent/Facility Connected Application -Remote Collocation - Decommissioning Overview process. Collocation application forms can be found under Applications and APOT forms table in the Collocation - General Information.

The ability to request Collocation - Synchronization Testing Overview is also available with Facility Connected (FC) Collocation.

If Copper Entrance facility is to be utilized for DS1 UNEs you must also provide the following circuit transmission information on the Collocation Application:

  • Length of cable between the Point of Interconnection (C-POI) and the CLEC repeater or equivalent unit
  • Cable Gauge
  • Whether the cable is screened or shielded. If neither, are the transmit and receive pairs in separate cables? If not, what is the binder group and pair information? You must provide sufficient pair separation when ordering DS1's to mitigate possible cross-talk problems (pursuant to Technical Publication, Interconnection and Collocation for Transport and Switched Unbundled Network Element and Finished Services, 77386
  • Total simplex resistance of the cable plus the repeater power supply (this information should be provided in the Remarks section of your LSR or ASR)

Back to Top

Provisioning and Installation

General provisioning and installation activities are described in the Provisioning and Installation section of Collocation - General Information.

Qwest will perform continuity testing from the C-POI to the block or panel. Any problems following turnover will be resolved utilizing the Maintenance and Repair process.

Back to Top

Maintenance and Repair

General maintenance and repair activities are described in the Maintenance and Repair section of Collocation - General Information.

Back to Top

Billing

General billing activities are described in the Billing section of Collocation - General Information.

Back to Top

Training

Local Qwest 101 "Doing Business with Qwest"

  • This introductory web-based training course is designed to teach the Local CLEC and Local Reseller how to do business with Qwest. It will provide a general overview of products and services, Qwest billing and support systems, processes for submitting service requests, reports, and web resource access information. Click here to learn more about this course and to register.

Collocation

View additional Qwest courses by clicking on Course Catalog.

Back to Top

Contacts

To identify your Qwest Wholesale Collocation Service Manager email colo@qwest.com. If a Qwest Wholesale Collocation Service Manager has not been assigned, one will be assigned.

Qwest contact information is located in Wholesale Customer Contacts.

Back to Top

Frequently Asked Questions (FAQs)

FAQ's will be developed based on your feedback.

Back to Top

Last Update: January 31, 2008

Legal Notices | Privacy | Wholesale Legal Notice