Network Disclosure Announcement #715
Copper Retirements in Arizona, Colorado, Iowa, Utah, Washington and Wyoming
| First Implementation Date: |
December 18, 2009
|
| Original Date Posted: |
November 5, 2009
|
| Summary: |
Copper Retirements are necessary to respond to various factors in the Outside Plant, including road construction, maintenance problems, and growth accommodation. Replacement cables may be either copper or fiber. Specific information will be provided with each disclosure.
|
| Locations, Timing of Deployments & Interface Requirements: |
The following gives additional details on the copper retirement(s):
|
| STATE |
WIRE CENTER |
PLANNED COMPLETION OR RETIREMENT DATE |
DA (s) |
Job # |
FDI Address(es) |
Replacing |
| AZ |
Phoenix East PHNXAZEA |
02-26-2010 |
211064 |
92132ZD |
I 1521 N Project Dr & I 5005 E McDowell Rd |
One of the existing copper feeder cables has been scheduled for removal and retirement. The existing working facilities will be moved to another cable working at I 1521 N Project Dr. The Loop Make-up and dB loss will change. The new LMU equals 20.230KF 24GA and 1.470KF 26GA. The dB loss changes to 41.960dB @ 28 KHz which is a change of +12.32dB loss. The new LMU for I 5005 E McDowell Rd equals 19.68KF 24GA and 1.170KF 26GA. The dB loss changes to 40.130dB @ 28 KHz which is a change of +12.89dB loss. The retirement of these cables are not CLEC impacting.. |
| AZ |
Prescott PRSCAZMA |
12-31-2009 |
117531 |
91131XS |
3212 Williamson Valley Rd |
THIS JOB REPLACES .12KF OF 24 GAUGE CABLE WITH .19KF OF 24 GAUGE CABLE FOR AN INCREASED DB LOSS OF +.13DB. |
| CO |
Aspen ASPECOMA |
01-04-2010 |
416231 |
H92A176 |
1450 Maroon Creek Rd |
Retirements for copper cable sections are as follows: BEFORE 2,310' of BKMS-25 @ 28 KHz = 4.012 dB loss AFTER 2,525 of ANMW-25 @ 28KHz = 4.386 dB loss. Change of +0.374 dB loss. |
| CO |
Pikeview CLSPCOPV |
12-30-2009 |
113781 |
92232B4 |
1375 Woodmen Rd |
Section throw. Before: 1152' OF 24 GA = 1.83 DB LOSS AT 28 KHZ After: 1336' of 24 ga = 2.11 DB loss at 28 KHz Negative impact to loop makeup of 0.28 DB loss Section two: Before: 75' of 24 ga = .13 DB loss at 28 KHz After: 175' of 24 ga = .29 DB loss at 28 KHz Negative impact to the loop make up of .16 DB loss Section three: Before: 312' of 24 ga = .52 DB loss at 28 KHz After: 422' of 24 ga = .70 DB loss at 28 KHz Negative impact on the loop make up of .18 DB loss Section four: Before: 250' of mixed ga = .30 DB loss at 28 KHz After: 316' of 24 ga = .53 DB loss at 28 KHz Negative impact to the loop make up of .23 DB loss |
| IA |
Mason City MSCYIATC |
02-26-2010 |
Route 1 |
92C1LC4 |
Route 1 |
Before: 3,009 feet of 24 gauge @ 28 Khz = 4.72Db After: 3,548 feet of 24 gauge @ 28 Khz = 5.62 Db Change of +.9 Db loss Before: 3,319 feet of 22 gauge @ 28 Khz = 3.62 Db After: 3.548 feet of 22 gauge @ 28 Khz = 3.89 Db Change of +.27 Db loss Before: 2,982 feet of 19 gauge @ 28 Khz = 1.88 Db After: 3,548 feet of 22 gauge @ 28 Khz = 3.89 Db Change of +2.01 Db loss |
| UT |
Brigham BGCYUTMA |
01-30-2010 |
111411 |
H86A513 |
1497 S Hwy 89 |
US DOT is rebuilding the Migrotory Bird Refuge Rd The Db loss calculations for the individual copper cable sections is: Before: loop length=11230 ft total loop resistance = 382 ohms longest single bridge tap = 9820 ft total bridge tap = 9820 ft probable loop current = 42 ma loss@ 1004 hz = 4.43 db After: loop length=11280 ft total bridge=9820 ft loop resistance=385 ohms loop current=42 ma loss@ 1004 hz=4.46db |
| WA |
Pasco PASCWA01 |
12-31-2009 |
250601 |
92W2G1X |
X 83-178S6 |
Road improvements by the State of Washington at the intersection of Hwy 12 and 5th Street are causing Qwest to remove copper feed and switch to fiber based services. This will cause a decrease of .6.71db loss at 1004hz. All existing services will continue to be supported. |
| WY |
Powell POWLWYMA |
12-18-2009 |
411900 |
9271BXK |
5240 Hwy 14A |
Before: 8264' 22ga @ 28KHz = 9.830 / 271.885 OHMS / 2.020 @ 1004Hz After: 8264' 24ga @ 28KHz = 14.010 / 432.207 OHMS / 2.510 @ 1004Hz Change of +4.18dB loss. |
|
| Additional Information: |
Any customer premises equipment vendor/manufacturer or enhanced services provider desiring additional technical information in conjunction with this Disclosure can contact:
Georganne Weidenbach
Regulatory Compliance Manager
Georganne.Weidenbach@qwest.com
|
This Network Disclosure is available as a PDF download. If you need to print Network Disclosures, the PDF file will give you more flexibility and a higher quality printout than will a Web page, which is designed to be viewed with a Web browser. If you need the Adobe Reader, you can download it for free from Adobe's Web site.
Back to Top - Net Disclosure Main Page
Net Disclosures Listed Numerically
Questions regarding Network Disclosure information can be referred to the individual listed on the Disclosure Announcement or e-mail Dean Martineau, Qwest's Manager of Network Disclosures at a.martineau@qwest.com.
|