Network Disclosure Announcement #709
Copper Retirements in Arizona, Colorado, Iowa, Minnesota, New Mexico and Wyoming
| First Implementation Date: |
November 20, 2009
|
| Original Date Posted: |
September 23, 2009
|
| Summary: |
Copper Retirements are necessary to respond to various factors in the Outside Plant, including road construction, maintenance problems, and growth accommodation. Replacement cables may be either copper or fiber. Specific information will be provided with each disclosure.
|
| Locations, Timing of Deployments & Interface Requirements: |
The following gives additional details on the copper retirement(s):
|
| STATE |
WIRE CENTER |
PLANNED COMPLETION OR RETIREMENT DATE |
DA (s) |
Job # |
FDI Address(es) |
Replacing |
| AZ |
Green Valley GNVYAZMA |
11-20-2009 |
N/A |
9212VYQ |
1 S SANTA BELIA |
Road Project by the Pima County required that F1 cables be re-routed to avoid conflict. Before: F1: 1104' 24ga+ 1846'26ga @28khZ=6.390dB After: F1: 3405'24ga @ 28khZ= 5.850dB Difference=-.24dB |
| AZ |
Maryvale PHNXAZMY |
12-28-2009 |
220111 |
92131NH |
4102 N 64TH DR |
This job is replacing 354ft of 50 pr 24 ga with 410 ft of 24 ga cable of 24 ga .from xbox 4102 n 64th dr approx 1.068 kf length is 56 ft longer. db .65 to .75db. |
| AZ |
Tempe Main TEMPAZMA |
12-29-2009 |
111262 |
92133KU |
HVP 901 W VANBUREN ST |
THIS JOB WILL REPLACE 1200' OF 22 GUAGE CABLE WITH A LOSS OF 1.400db WITH 1210' OF 22 GUAGE CABLE WITH A LOSS OF 1.410dB |
| CO |
Denver Capitol Hill DNVRCOCH |
02-10-2010 |
N/A |
9222Z5E |
N/A |
THIS JOB REMOVES A 26 GUAGE 4200 PR CABLE AND ALL WORKING CIRCUITS WILL BE CUT TO EXISTING SPARES IN ANOTHER CABLE. DB loss calculations are as follows: IT 1670 Broadway old 21.48DB new 20.06DB -1.42DB IT140 E 19th Av old 20.68DB new 19.95DB -.73DB It 1800 Grant Old 17.00 DB new 16.92db -.08DB I 524 E 17th Av old 12.61 DB new 12.47 -.014DB It 601 E 18th Ave (MCI) old 13.82 DB new 13.76 DB -.006 DB |
| CO |
Denver Northeast DNVRCONE |
12-23-2009 |
111921 |
92233AV |
9085 Moon Ct |
This job will replace a worn, wet aerial 25 pair cable. This will place 300' ANMW-50, 455' ANMW-25, 755' 6.6m strand, 1-25 pair terminal and 4-12 pair terminals. The dB loss calculations for the sections are: Before- 755' BHAS-25 @ 28KHz = 0.800. After- 300' ANMW-50 & 455' ANMW-25 @ 28KHz = 1.220. This is a change of +0.420dB. |
| CO |
Westminster WMNSCOMA |
12-20-2009 |
210882 |
9222YZY |
3691 W 82 Ave |
replacing 166' of 26 ga with 868' of 24 ga. |
| IA |
Des Moines West DESMIAWS |
01-06-2010 |
130003 |
92C1KKY |
4950 Hickman Rd |
RELOCATION OF FDI TERMINAL FROM 4950 HICKMAN RD TO 5000 HICKMAN RD WILL RESULT IN INCREASE TO F1 AND F2 LOOP LOSS. All existing circuits and service types will continue to be supported. Existing distribution loop make-ups from X 4950 HICKMAN RD will be extended 217 feet. 4950HIKMAN,601-700 Before - 426' of AFTW-900, ALTW-900, AFTW-300 (F1+F2) @ 28 KHz = 1.08 dB @ 1004 Hz = 0.38 dB @ DSL = 1.68 dB After - 643' of ANMW-900, ANMW-400, 165' AFTW-200 (F1+F2) @ 28 KHz = 1.44 dB @ 1004 Hz = 0.45 dB @ DSL = 2.60 dB Existing distribution loop make-ups from X 4950 HICKMAN RD will be extended 1004 feet. 4950HIKMAN, 901-1800 Before - 105' of AFTW-900 (F1) @ 28 KHz = 0.28 dB @ 1004 Hz = 0.23 dB @ DSL = 0.34 dB After - 1109' of ANMW-900 (F1+F2) @ 28 KHz = 1.76 dB @ 1004 Hz = 0.51 dB @ DSL = 3.26 dB |
| MN |
Little Falls LTFLMNLF |
12-16-2009 |
110203, 110402, 110403, 110504, 110702, 110802, 210203, 210204, 210302, 410202, 410204, 410405, 410406, 410702, 413004, 430102, 430402, 430602, 410503 |
92M1Y5X |
N/A |
RPL DEF FEEDER SECTION OF UG CABLE (C0 TO MH 103). Work begins at the CO vault. The dB loss calculations for the individual cable sections are: BEFORE: AFTER: 215' 19GA @ 28KHz=.20dB 250' 24GA @ 28KHz= .25dB Chg of + .05 dB requires notification disclosure 218' 24GA @ 28KHz=.24dB 250' 24GA @ 28KHz= .25dB Chg of + .01 dB requires notification disclosure 641' 22GA @ 28KHz=.30dB 675' 24GA @ 28KHz= .38dB Chg of + .08 dB requires notification disclosure |
| MN |
Rochester ROCHMNRO |
01-18-2010 |
251102 |
92M1YVK |
OLD SAI (X 3814 SE 25 ST) NEW SAI X 2515 MARION RD SE |
Qwest will relocate the existing Sai from the intersection of 25th St SE & Marion Rd SE to 2515 Marion Rd SE. The new Sai will be 100% pair gain fed from an existing remote terminal. This job will remove the existing C.O. copper F-1 pairs as part of the project to eliminate the copper F-1 pairs to this area which is being impacted by the 4th Street bridge replacement. No C.O. copper F-1 pairs will remain at X 2515 Marion Rd SE. The before loss to X 3814 SE 25 ST is 49.39 dB at 28Khz which includes 3,695 feet of ANAW, 17,314 feet of ANMW and 6,062 feet of ANTW cables (27.07 Kft). The after loss to X 2515 Marion Rd SE is .24 dB at 28Khz which includes 145 feet of ANMW cable (.145 Kft). All existing CLEC circuits will work at the new Sai at the completion of the job. |
| MN |
Rochester ROCHMNRO |
01-18-2010 |
251002 |
92M22X5 |
2141 Marion Rd SE |
Qwest will re-feed the existing Sai at 2141 Marion Rd SE. It is presently fed from C.O. based copper pairs and will be cut to an existing RT. The Sai will be 100% pair gain fed. This job is part of the project to eliminate the copper F-1 pairs to this area which is being impacted by the 4th Street bridge replacement. At the completion of this job, no copper F-1 pairs will be available to this Sai. The before loss to X 2141 Marion Rd SE is 41.80 dB at 28Khz which includes 13,871 feet of ANMW and 7,336 feet of ANTW cables (21.21 Kft). The after loss to X 2141 Marion Rd SE is 5.36 dB at 28Khz which includes 3,397 feet of ANMW cable (3.40 Kft). All existing CLEC circuits will continue to work at the completion of this job. |
| NM |
Alamogordo Main ALMGNMMA |
01-01-2010 |
114101 |
9251TUM |
7196 N Hwy 70 |
Replace cable due to erosion of arroyo causing pole to collapse and cable to fall into arroyo job will go aerial to buried changing gauge from 19 to 24 before after 604'of bhbh-25 @28khz=0.390 620' of anmw-25@28khz=0.1.120 change of 0.730db. |
| NM |
Albuquerque ALBQNMCR |
11-25-2009 |
110601 |
9251T1C |
35.3 Corrales Rd NW |
THIS JOB WILL REPLACE EXISTING COPPER CABLE (77FT OF 24GA WITH A DB LOSS = 0.150). IT WILL BE REPLACED WIRH 150FT OF 24GA (0.280DB) THE MINIMAL LOSS WILL NOT AFFECT THE LOOP. |
| NM |
Anthony ANTHNMMA |
01-01-2010 |
122401 |
9251TE1 |
4695 Saltbrush |
retirement date 01/01/2010 cable replaced due to dona ana county road project request the removal of poles which is requiring Qwest to go buried before after 404'of bhbh-25 @28khz=0.260 330' of anmw-25@28khz=0.640 change of 0.380db. |
| WY |
Cody CODYWYMA |
12-01-2009 |
111001 |
9271BEJ |
13.2 RL13 |
F1 Before: 285' ANAW-2 @ 28KHz = 0.310 / 9.376 Ohms / 0.230 @ 1004Hz After: 412' ANAW-2 @ 28KHz = 0.440 / 13.554 Ohms / 0.260 @ 1004Hz Change of +0.13dB loss. F2 Before: 372' ANAW-100 @ 28KHz = 0.400 / 12.238 Ohms / 0.250 @ 1004Hz After: 472' ANAW-100 @ 28KHz = 0.500 / 15.528 Ohms / 0.270 @ 1004Hz Change of =0.10dB loss. F2 Before: 279' ANMW-25 @ 28KHz = 0.330 / 10.246 Ohms / 0.240 @ 1004Hz After: 512' ANMW-25 @ 28KHz = 0.570 / 17.620 Ohms / 0.280 @ 1004Hz Change of +0.24dB loss. |
| WY |
Lander LNDRWYMA |
11-25-2009 |
213701 |
9271C2G |
37.9 rl18 |
This job will replace 300ft of BHBH-200 cable that has been documented as defective beyond repair due to water. Before Job: 36.732kf with 9.940 dbs of loss @ 1004Hz and 868.790 total Ohms Resistance After Job: 36.732kf with 9.970 dbs of loss @ 1004Hz and 873.328 total Ohms Resistance This slight increase in ohms is due to replacing the 275 ft of 19 gauge cable with 275 ft of 22 gauge cable and is not service affecting. |
|
| Additional Information: |
Any customer premises equipment vendor/manufacturer or enhanced services provider desiring additional technical information in conjunction with this Disclosure can contact:
Georganne Weidenbach
Regulatory Compliance Manager
Georganne.Weidenbach@qwest.com
|
This Network Disclosure is available as a PDF download. If you need to print Network Disclosures, the PDF file will give you more flexibility and a higher quality printout than will a Web page, which is designed to be viewed with a Web browser. If you need the Adobe Reader, you can download it for free from Adobe's Web site.