Network Disclosure Announcement #708
Copper Retirements in Arizona, Iowa, Minnesota, New Mexico, North Dakota, South Dakota, Utah, and Wyoming
| First Implementation Date: |
October 29, 2009
|
| Original Date Posted: |
September 15, 2009
|
| Summary: |
Copper Retirements are necessary to respond to various factors in the Outside Plant, including road construction,
maintenance problems, and growth accommodation. Replacement cables may be either copper or fiber. Specific
information will be provided with each disclosure
|
| Locations, Timing of Deployments & Interface Requirements: |
The following gives additional details on the copper retirement(s):
|
| STATE |
WIRE CENTER |
PLANNED COMPLETION OR RETIREMENT DATE |
DA (s) |
Job # |
FDI Address(es) |
Replacing |
AZ |
Higley Main HGLYAZMA |
12-18-2009 |
410121 |
8212KPU |
SAI X 15620 S RECKER RD |
THIS JOB WILL REPLACE 686' OF 24 GUAGE CABLE WITH A LOSS OF 1.230db WITH 821' OF 24 GUAGE
CABLE WITH A LOSS OF 1.460dB |
AZ |
Maryvale PHNXAZMY |
12-14-2009 |
421771 |
9212ZPV |
7501 W Osborn Rd |
This job is replacing 100 pr with 50 and 25 and replcing existing 26 ga. 400 pr leaving
box with 400 pr 24 ga. A section of 400 pr is 22 gauge cable approx 362 ft with 497 ft of 24 gauge
with +.35 db loss difference.This is the only section that requires disclosure. The rest of the job
replaces 26 gauge with 24 ga inproving the db loss on the services. This section is approximately 397
ft south of the xbox 7501 w Osborn Rd. |
AZ |
Phoenix South PHNXAZSO |
12-18-2009 |
310831 |
92132Z3 |
SAI X 9201 S 19TH AVE |
THIS JOB WILL REPLACE 1281' OF 22 GUAGE CABLE WITH A LOSS OF 1.490db WITH 1281' OF 24 GUAGE CABLE WITH A LOSS OF 2.220dB |
IA |
Cedar Rapids CDRRIANO |
10-29-2009 |
211505 |
92C1HGE |
279 Collins Rd NE |
The City of Cedar Rapids is improving the 1st Ave/Hwy 151 cooridor up to Collins Rd NE/Hwy100.
Qwest has a number of buried cables that are conflict with the construction of this city project
Before: After:
180' of BKTH-600 @ 28KHz = .470 370' of ANMW-400 @ 28KHz = .610
Change of +0.14 dB loss.
421' of ANMW-400 @ 28KHz = .690 456' of ANMW-400 @ 28KHz = .750
Change of +0.06 dB loss.
125' of AFMW-200 @ 28KHz = .210 180' ofANMW-200 @ 28KHz = .300
Change of +0.09 dB loss. |
MN |
Hopkins HPKNMNHO |
12-20-2009 |
410808 |
92M23KU |
N/A |
REPLACING 75'(F) OF BHAA-100 PAIR WITH 100'(F) OF ANAW-100 PAIR ADDING .03db loss @28KHz. |
MN |
Rochester ROCHMNRO |
01-18-2010 |
240502 |
92M236B |
LD SAI (X AA17-B) NEW SAI X 8701 COUNTY 9 RD E |
Qwest will relocate the existing Sai from the intersection of 70th St SE & Co RD 9 to 8701
COUNTY 9 RD E. The new Sai will be 100% pair gain fed from an existing remote terminal. This job will
remove the existing C.O. copper F-1 pairs as part of the project to eliminate the copper F-1 pairs to
this area which is being impacted by the 4th Street bridge replacement. No C.O. copper F-1 pairs will
remain at X 8701 County 9 Rd E at the completion of this job. The before loss to X AA17-B is 78.10 dB
at 28Khz which includes 6,148 feet of ANTW and 26,352 feet of ANMW and 13,949 feet of ANAW cable (46.45
Kft). The after loss to X 8701 County 9 Rd E is 14.13 dB @ 28 Khz which includes 180' of ANMW and 11,520
feet of ANAW cable (11.70 Kft). All existing Clec circuits will work at the new Sai at the completion
of the job. |
MN |
Rochester ROCHMNRO |
01-18-2010 |
251103 |
92M22X4 |
SHADOW DR & 29 ST SE |
Qwest will re-feed the existing Sai at Shadow Dr & 29 St SE. It is presently fed from a SLC96
RT and will be cut to a TA1500 RT. The Sai is 100% pair gain fed from an existing remote terminal and
will remain a 100% pair gain sai. This job is part of the project to eliminate the copper F-1 pairs
to this area which is being impacted by the 4th Street bridge replacement. At the completion of this
job, no copper F-1 pairs will be available to this Sai. The before and after loss to X Shadow Dr & 29
St SE is 11.86 dB at 28Khz which includes 6,196 feet of ANMW and 575 feet of ANTW cables (6.77 Kft).
All existing Clec circuits will continue to work at the completion of this job. |
MN |
St Peter STPRMNSP |
02-01-2010 |
310502 |
H9MA037 |
1305 TH 169 |
The design point for this area prior to this work being completed is 5.54kFt from the central office
with a loss at 28kHz of 12.91dB.
Cable counts affected: 4,1-200; 4,1201-1425; 4,1451-1475; MH12C,951-1000; 4,1501-1600; 6,1201-1400; & 6,1401-1500.
The cable will be rerouted due to construction at the southeast corner of Jefferson Ave and St Hwy
169 in St Peter, Minnesota.
485ft of 26 gauge cable will be removed and replaced with 760ft of 24 gauge cable resulting in a net
loss @ 28kHz of 12.92dB- a loss increase of 0.01 dB. Design point after completion of work will be 5.815kFt
from the central office. |
ND |
Fargo FARGNDBC |
11-06-2009 |
410306 |
92F15U2 |
950 14 ST N |
REPLACE DISTRIBUTION CABLE THAT HAS A BURIED 3-WAY SPLICE. EXISTING COPPER CABLE (99 FEET
OF 900- 22 GAUGE @ 28khZ WITH A DB LOSS OF 0.110). THIS WILL BE REPLACED WITH 130 FEET OF 900-24 GAUGE
@ 28khZ WITH A DB LOSS OF 0.220 DB. THE MINIMAL LOSS OF +0.110db WILL NOT AFFECT THE LOOP. |
NM |
Aztec Main AZTCNM03 |
10-29-2009 |
N/A |
9251TP1 |
N/A |
Job replaces 324' of 26ga copper with 520' of 24ga copper. Change of +0.020dB loss. |
NM |
Las Cruces Main LSCRNMMA |
12-21-2009 |
327501 |
9251SYT |
X 68 RL81 |
Replace detiorated buried cable along Calle De Santa Ana and Calle Quinta. F2 cable
1014,2151-2175.
EXISTING:Abandon in place 492' of BHAA-25. 0.6 db loss at 28 KHz
PROPOSED: Place 487' of buried ANMW-25. 0.9 db loss at 28 KHz.
Difference is +0.3 db loss |
SD |
Yankton YNTNSDCO |
11-01-2009 |
410604 |
92T1631 |
X 38-2 |
Qwest will relocate 410 feet of 19 gauge cable due to conflicts with a box culvert reconstruction
on 438th Ave one mile North of SD Hwy 50 near Yankton SD. The cable will be replaced with 410 feet of
24 gauge cable. This will result in an loss increase of .08 db at 1004 Hz and .420 db at 28 KHz. This
cable relocation is near the end of the cable loop and will have little impact to the services that
are currently available in this area. |
UT |
Midvale MDVAUTMA |
10-30-2009 |
424201 |
H96A059 |
7945 S 1300 WEST |
The work begins at 1.290kf from the Midvale CO.
The dB loss calculations for the individual copper cable sections are:
Before
1.277kf AFMW-400 @ 28 KHz 2.020
After
1.460kf ANMW-400 @ 28 KHz 2.290
Change 0f 0.27 dB loss |
UT |
St George STGRUTMA |
11-01-2009 |
N/A |
9261YPW |
104 E. Tabernacle St |
Valley View Drive Bridge Proj. BRO-LC53(21)
St. George City is replacing the bridge over the Santa Clara River. Qwest had temporary aerial cables
spanning over the existing bridge. The city is requiring Qwest to relocate it's facilities underground
under the river. This job is the second phase of two jobs. This will be the permanent
construction to bore under the santa clara river with 4-4" conduits. Three manholes will need
to
be placed to be able to pull the required 2 1800 pr cables and 1 96 count fiber across the river.
The dB loss calculations for the individual copper cable sections are:
Before:
1354' of AFMW-600, ANMW-1200, AFMW-900 @ 1004KHz=0.61 db
After:
1449' of ANMW-1800, AFMW-900 @ 1004KHz=0.64 db
Change of +.03dB loss.
Before:
1343' of AFMW-900, ANMW-1200, ALAW-600 @ 1004KHz=0.54 db
After:
1463' of ANMW-1800, ALAW-600 @ 1004KHz=0.58 db
Change of +.04dB loss.
BEFORE:
775 FT OF 96 SMF CABLE
2.28 db @ 1310 MHZ
AFTER:
1600 FT OF 96 SMF CABLE
2.37 db@ 1310 MHZ
+.09 db loss. |
WY |
Gillette GLTTWYMA |
01-10-2010 |
330500, 331000, 331031, 331600, 340300, 340600, 340800, 341731, 341800, 343400 & 343500 |
9271BZM |
2891 Antler Rd., 1275 E. Southern Dr., 5200 Rourke Ave. 4801 Sleepy Hollow, 10351
S. Hwy. 59, 1 Hoe Crk. Rd., 727 Hoe Crk. Rd., 117.8 RL134R, 95.5 RL134R1, 2116 Bishop Rd. & 148.7 RL134W |
A 1022' section of a CXR "T"-Screen Cable feeding "T"-lines in the
south route of Gillette is going wet and needs to be replaced, 11,584' out of the C.O.
Before: 1,022' of 22 ga. @ 28 KHz = 1.08 db
After: 1,167 of 22ga. @ 28 KHz = 1.23 db
A change of +0.15 db. |
WY |
Sheridan SHRDWYMA |
11-12-2009 |
311201 |
9271C1C |
89 Woodland Park Rd |
Replace a section of deteriorated cable on Short Rd. Before 1696' 24ga 2.65 db loss, after 1949'
24ga 3.04 db loss for a difference of +.39 db loss |
|
| Additional Information: |
Any customer premises equipment vendor/manufacturer or enhanced services provider desiring additional technical information in conjunction with this Disclosure can contact:
Georganne Weidenbach
Regulatory Compliance Manager
Georganne.Weidenbach@qwest.com
|
This Network Disclosure is available as a PDF download. If you need to print Network Disclosures, the PDF file will give you more flexibility and a higher quality printout than will a Web page, which is designed to be viewed with a Web browser. If you need the Adobe Reader, you can download it for free from Adobe's Web site.