Network Disclosure Announcement #706
Copper Retirements in Colorado, Iowa, Minnesota and Utah
| First Implementation Date: |
November 16, 2009
|
| Original Date Posted: |
August 28, 2009
|
| Summary: |
Copper Retirements are necessary to respond to various factors in the Outside Plant, including road construction, maintenance problems, and growth accommodation. Replacement cables may be either copper or fiber. Specific information will be provided with each disclosure.
|
| Locations, Timing of Deployments & Interface Requirements: |
The following gives additional details on the copper retirement(s):
|
| STATE |
WIRE CENTER |
PLANNED COMPLETION OR RETIREMENT DATE |
DA (s) |
Job # |
FDI Address(es) |
Replacing |
| CO |
Denver North DNVRCONO |
12-01-2009 |
303433 |
9222ZU3 |
DIRECT FEED |
Replace 1634' OF 22 GA WITH 1634' OF 24 GA for maintenance. |
| IA |
Iowa City IWCYIATC |
11-19-2009 |
223412 |
92C1KQL |
4250 Napoleon St SE |
This job will replace 820' of BHBH-50 that was placed in 1970 on Sioux Ave and 480th St in the IWCYIATC exchange. This is buried air core cable that has been damaged by rodents and water rot. The db loss calculation for this section of cable is: Before: 820'of BHBH-50 @1004Hz = .260 After: 820' of ANAW-50 @1004Hz .340 |
| IA |
Waterloo WTRLIADT |
12-11-2009 |
590102 |
92C1J6K |
3490 W 4 ST |
This job will split an existing DA served by X 3490 W 4 St. and all ckts on the F2 3490W4,1-190 will cut to a new fiber DLC at 2316 W. Ridgeway Ave. All ckts cutting to the DLC will be supported. Cable retired on this job will not be replaced. |
| MN |
Rochester ROCHMNRO |
11-16-2009 |
240702 |
92M22HK |
6615 10 ST SE |
Qwest will turn up additional pair gain capacity at an existing remote terminal and Sai at 6615 10 St SE and remove the existing C.O. copper pairs from the Sai as part of the project to eliminate the copper F-1 pairs to this area which is being impacted by the 4th Street bridge replacement. At the completion of this job, no copper F-1 pairs will be available to the Sai and all existing circuits will continue to work. The before loss to X 6615 10 St SE is 74.19 dB at 28Khz which includes 160 feet of ANAW, 34,286 feet of ANMW and 5,813 feet of ANTW cables (40.26 Kft). The after loss to X 6615 10 St SE is .07 dB at 28Khz which includes 40 feet of ANMW cables (.04 Kft). |
| UT |
Logan Main LOGNUTMA |
12-14-2009 |
410102 |
9261YSK |
249 S 100 E |
The City of Logan project 100 E from 300 S to 500 S is being reconstructed and widened. Qwest facilities are presently in the path of this project. Relocation of these is required for work to be completed. The dB loss calculations for the individual copper cable sections is: Before: total loop resistance = 240 ohms loss @ 318000 = 13.23 db 196000 hz normalized = 11.06 db After: total loop resistance = 242 ohms loss @ 318000 = 13.25 db 196000 hz normalized = 11.08 db |
|
| Additional Information: |
Any customer premises equipment vendor/manufacturer or enhanced services provider desiring additional technical information in conjunction with this Disclosure can contact:
Georganne Weidenbach
Regulatory Compliance Manager
Georganne.Weidenbach@qwest.com
|
This Network Disclosure is available as a PDF download. If you need to print Network Disclosures, the PDF file will give you more flexibility and a higher quality printout than will a Web page, which is designed to be viewed with a Web browser. If you need the Adobe Reader, you can download it for free from Adobe's Web site.
Back to Top - Net Disclosure Main Page
Net Disclosures Listed Numerically
Questions regarding Network Disclosure information can be referred to the individual listed on the Disclosure Announcement or e-mail Dean Martineau, Qwest's Manager of Network Disclosures at a.martineau@qwest.com.
|