Qwest
Customer Service Search
Home - Residential - Small Business - Large Business - Partners - Wholesale
Network Disclosures


Network Disclosure Announcement #703

Short Term Public Notice Under Rule 51.333(a). Qwest's Internet address: http://www.qwest.com/disclosures.

Copper Retirements in Arizona, Colorado, Iowa, Minnesota, Montana, Nebraska, New Mexico, Oregon and Utah

First Implementation Date:

September 18, 2009

Original Date Posted:

August 6, 2009

Summary:

Copper Retirements are necessary to respond to various factors in the Outside Plant, including road construction, maintenance problems, and growth accommodation. Replacement cables may be either copper or fiber. Specific information will be provided with each disclosure.

Locations, Timing of Deployments & Interface Requirements:

The following gives additional details on the copper retirement(s):

STATE WIRE CENTER PLANNED COMPLETION OR RETIREMENT DATE DA (s) Job # FDI Address(es) Replacing
AZ Phoenix Northwest PHNXAZNW 12-31-2009 414072 9212ZUS 3709 W. Marlette Ave Qwest is replacing two spans of aerial 24 gauge copper feeder cable and two spans of aerial 24 gauge copper distribution cable with 24 gauge direct buried feeder and distribution cable. The cables provide (F1) feeder facilities to SAI 3709 W. Marlette Ave., and (F2) distribution facilities to several serving terminals within the distribution area. The dB loss calculations for the cable sections are: Before After 96' BKMA-400 40' AFMW-900 @ 28 KHz = 0.250 147' ANMW-400 @ 28 KHz = 0.280 Change of +0.03dB loss. 96' BKMA-200 @ 28 KHz = 0.180 163' ANMW-200 @ 28 KHz = 0.300 Change of +0.12dB loss. 10' BKMA-300 40' AFMW-900 @ 28 KHz = 0.090 62' ANMW-300 @ 28 KHz = 0.120 Change of +0.03dB loss. The new (F1) loop will remain at 13.7Kft. to SAI X 3709 W. Marlette Av., and will continue to support all existing types of circuits.
CO Denver East DNVRCOEA 10-23-2009 322113 H92A114 8440 E 21 AV REPLACE 556' ANMW-25 WITH 813' ANMW-25 FOR RELOCATION JOB. The dB loss calculations for the individual copper cable section is: Before - 556' ANMW-25 @ 28KHz = 0.910 After - 813' ANMW-25 @ 28KHz = 1.310 This is a change of + 0.400dB.
IA Carlisle CRLSIACO 10-30-2009 120002 92C1JBW SAI X 435 MAIN Distribution cable must be relocated due to the land slide on the hill on the south side of Highway 5 on the west edge in the City of Carlisle, Iowa. There is a negitive impact on the following SAI cable count: 435MAIN, 1426-1475 and 1551-1600. Existing 1580' of 24 gauge pic loss @ 28 KHz =2.48 Increased loss=1.26 dB @ 28 KHz
IA Vinton VNTNIACO 09-25-2009 341002 92C1KD3 400-18 The dB loss calculation for the individual copper cable section is: Before: After: 900' of AJAA-25 @ 28KHz = .950 970' of ANAW-50 @ 28Khz = 1.03 Change of +0.08dB loss. A section of F1 cable that feeds the SLC at X 400-18 is defective and needs to be replaced. This job section throws a new 50pr 22 gauge cable to relieve defective section along Hwy 218.
MN Winona WINOMNWI 09-18-2009 230602 92M22N7 E15-A Winona County is replacing a bridge in the city of Picwick. Qwest currently has cable in conduit on the bridge, the cable has been temped out so the bridge can be demolished & a new one put in its place. When the new one is done, Qwest's cable will be encased in concrete in the deck of the bridge. Bridge #85563 located at CSAH 7 & CSAH 8. The work begins at 69.3kf from the Winona central office or .663kf from the remote terminal. The db loss calculation for the individual copper cable section is as follows: Before: 380'of BHBH-50, 75'of BHBH-50 @28KHz=.260 After: 390'of ANMW-100, 115'of ANMW-50@28KHz=.830a change of +.57db loss. Before: 325'of AFAW-1@28KHz=.350 After: 390'of ANMW-1@28KHz=.640db a change of +.29db loss.
MT Victor VCTRMTMA 09-18-2009 120431 120641 H94A004 2630 Meridian Rd, x 15.0 rl1 Qwest is rerouting buried cable in conflict with a highway project. The following are the db calculations for cable sections. 1516' of 24 ga will be replaced with 2179' of 24 ga. The loss is increased by +1.01db. 2576' of 24ga will be replaced with 1766' of 24 ga. The loss is decreased by -2.26db.
NE Omaha 78th St OMAHNE78 12-16-2009 115602 91B17B5 10300 N 60 REPLACE 565' OF BHBH-200 WITH 501' OF ANAW-200 BEFORE: 565' OF BHBH-200 HAS .230db LOSS @ 1004hz AFTER: 501' OF ANAW-200 HAS .270db LOSS @ 1004hz A NEGATIVE DIFFERENCE OF .030db
NE Omaha 84th St OMAHNE84 04-08-2010 116002 H9BA002 4818 S 108 ST This job will lengthen the loop by a total of 0.064 Kf, the F1 and all the F2 cables will be increased. The dB loss calculations for the F1/F2 is: Terminal 10828 John Galt Blvd / SAI x4818 S 108 St OLD F2 route of 2.098 KF @ 28 KHz=3.520dB & 1004Hz=0.870dB NEW F2 route of 2.162 KF @ 28 KHz=3.610dB & 1004Hz=0.890dB Change of +0.09dB loss @ 28 KHz & +0.020dB loss @ 1004 KHz. The existing loop 1.758Kf of 24 ga and 0.360Kf of 26 ga is being lengthned by 0.064Kf of 24 ga to a new loop of 1.822Kf of 24 ga and 0.360Kf of 26 ga The working circuits are derived from the RT 1.625 Kf from existing terminal
NM Santa Fe Main SNFENMMA 11-20-2009 ALL 9251T37 35.9 Old Las Vegas Hwy Qwest is removing all copper f1 from SAI 35.9 Old Las Vegas HWY and cutting to pair gain from an existing RT located also at 35.9 Old Las Vegas HWY. The existing number of 505-820-6582 ( F! 26GA = 1.408 KF, 24GA = .090 KF, 22GA = 27.346 KF, 19GA = 8.476 KF. F2 24GA = 3.113 KF) will be cut to the RT. This RT does not support LNSHR. The new F1/F2 loop will be 3.413 KF. .
OR Springfield SPFDOR01 10-20-2009 312211 91R1Y6Z 86479 Franklin Bv Removal/Retirement of existing copper cable resulting in a complete copper service type withdrawal. Converting from CO based copper feeder cables to pair gain derived pairs (fiber or copper fed systems) resulting in a complete copper service type withdrawal; DSL type services. Service to this area had been provided through an ADAC-600 which can not be restored. Working pairs were thrown through an ADMC-900 which is being targeted by copper thieves. It is clear that both cables must be removed from plant. All services currently fed on copper will now need to be fed with fiber supported equipment.
UT American Fork AMKFUTMA 03-10-2010 213901 9261YDA 575 East 110 South AMERICAN FORK CITY ROAD AND PROPERTY INPROVEMENT JOB IS REQUIRING . QWEST TO RELOCATE ITS AERIAL FACILITIES TO UNDERGROUND. THIS JOB WILL PLACE 616' OF 200PR CABLE, REMOVE EXISTING AERIAL CABLE , REMOVE QWEST POLES .DB LOSS CALCULATION ARE AS FOLLOWS: BEFORE: 590'BKMH-200@28KHZ=.960 AFTER 616' OF ANMW-200 @28 KHZ=1.000 THIS EQUALS A CHANGE OF + 0.04.
Additional Information:

Any customer premises equipment vendor/manufacturer or enhanced services provider desiring additional technical information in conjunction with this Disclosure can contact:

Georganne Weidenbach
Regulatory Compliance Manager
Georganne.Weidenbach@qwest.com

This Network Disclosure is available as a PDF download. If you need to print Network Disclosures, the PDF file will give you more flexibility and a higher quality printout than will a Web page, which is designed to be viewed with a Web browser. If you need the Adobe Reader, you can download it for free from Adobe's Web site.

Back to Top - Net Disclosure Main Page
Net Disclosures Listed Numerically

Questions regarding Network Disclosure information can be referred to the individual listed on the Disclosure Announcement or e-mail Dean Martineau, Qwest's Manager of Network Disclosures at a.martineau@qwest.com.

Copyright © 2009 Qwest | All Rights Reserved | Legal Notices | Privacy Policy