Network Disclosure Announcement #696
Copper Retirements in Colorado, Minnesota, Nebraska, New Mexico and Washington
| First Implementation Date: |
July 31, 2009
|
| Original Date Posted: |
June 12, 2009
|
| Summary: |
Copper Retirements are necessary to respond to various factors in the Outside Plant, including road construction, maintenance problems, and growth accommodation. Replacement cables may be either copper or fiber. Specific information will be provided with each disclosure.
|
| Locations, Timing of Deployments & Interface Requirements: |
The following gives additional details on the copper retirement(s):
|
| STATE |
WIRE CENTER |
PLANNED COMPLETION OR RETIREMENT DATE |
DA (s) |
Job # |
FDI Address(es) |
Replacing |
| CO |
Evergreen EVRGCOMA |
09-30-2009 |
312911 |
9222YAB |
388 Witter Gulch Rd |
replacing 607' of 22 ga with 824' of 22 ga. |
| MN |
St Cloud STCDMNTO |
09-03-2009 |
221202 |
92M21U4 |
6443 Maynew Lake Rd NE |
BEFORE: AFTER: 80' 19g &470' 22g@28KHx=.550 553' 24g@28KHz=.900 Chg of +.351dB loss 4346' 22g & 992' 24g@28KHz=6.7 5183' 24g@28KHz=8.5 Chg of +1.8 785' 19g, 4260' 22g & 992' 24g@28KHz=7.2 5837' 24g@28KHz=9.680 Chg of +2.48 |
| MN |
St Peter STPRMNSP |
11-30-2009 |
330402 |
C9MA055 |
D10A |
THIS JOB WILL REPLACE 500 FEET OF 22 GUAGE AERIAL CABLE WITH A Db LOSS OF 0.530 WITH 500 FEET OF BURIED 24 GUAGE WITH A Db LOSS 0.820. |
| NE |
Ainsworth ANWONENW |
07-31-2009 |
410303 |
92B172T |
X E 1 S |
Old F2 route of 3.01KF @ 28KHZ=1.90db. New F2 route of 3.21KF @ 28KHZ=2.02db. Change of +.12db Replacing a AJBW-6pr cable with BSW-6PR-19GA between tea 345-10 to a mtc test point. |
| NM |
Corrales ALBQNMCR |
08-15-2009 |
213301 |
9251RG3 |
815 Ortega Rd NW |
This job will replace an existing cable (115ft of 22GA with dB loss of 0.140). The 115' will be replaced with 255' of 24GA with a dB loss = 0.470 |
| WA |
Aberdeen ABRDWA01 |
08-30-2009 |
324102 |
92W2AVA |
791 SR 105 |
This job replaces approximately 6 miles of aerial feeder and distribution cables along State Route 105 (Westport Hwy) from the Aberdeen city limits (16.6KF) to the Aberdeen wire center exhange boundary. The dB loss calculations for the individual copper cable sections @ 28KHz are: Before: 31,515ft of 22ga = 38.370dB. After: 24,265ft of 22ga and 7250ft of 24ga =42.130dB. A change of 3.76dB. Before: 24,265ft of 19ga and 7250ft of 22ga = 25.680dB. After: 24,265ft of 22ga and 7250ft of 24ga =42.130dB. A change of 16.45dB. |
|
| Additional Information: |
Any customer premises equipment vendor/manufacturer or enhanced services provider desiring additional technical information in conjunction with this Disclosure can contact:
Georganne Weidenbach
Regulatory Compliance Manager
Georganne.Weidenbach@qwest.com
|
This Network Disclosure is available as a PDF download (file size: 144Kb). If you need to print Network Disclosures, the PDF file will give you more flexibility and a higher quality printout than will a Web page, which is designed to be viewed with a Web browser. If you need the Adobe Reader, you can download it for free from Adobe's Web site.
Back to Top - Net Disclosure Main Page
Net Disclosures Listed Numerically
Questions regarding Network Disclosure information can be referred to the individual listed on the Disclosure Announcement or e-mail Dean Martineau, Qwest's Manager of Network Disclosures at a.martineau@qwest.com.
|