Network Disclosure Announcement #690
Copper Retirements in Minnesota
| First Implementation Date: |
June 12, 2009
|
| Original Date Posted: |
May 4, 2009
|
| Summary: |
Copper Retirements are necessary to respond to various factors in the Outside Plant, including road construction, maintenance problems, and growth accommodation. Replacement cables may be either copper or fiber. Specific information will be provided with each disclosure.
|
| Locations, Timing of Deployments & Interface Requirements: |
The following gives additional details on the copper retirement(s):
|
| STATE |
WIRE CENTER |
PLANNED COMPLETION OR RETIREMENT DATE |
DA (s) |
Job # |
FDI Address(es) |
Replacing |
| MN |
Oak Grove OKGVMNOG |
09-24-2009 |
480402 |
92M1Y5N |
CR 5 & 167TH |
Due to a road job in the City of Ramsey. Some of the existing buried cables, F2, in DA 480402 (19ga., 22ga. & 26ga.) will be abandoned and replaced with new 24 ga. cables, in some of the areas covered by this job. All working services in the F2 cables (19ga., 22ga., & 26 ga.) will be cut to the new F2 (24 ga.) cables.The existing cable lengths and new cable lengths will change in some of the sections. OLD CABLE NEW CABLE 2451' 22ga. @ 28 KHz=2.62 3545' 24 ga. @ 28KHz=5.61 Change of +2.99dB loss. 305' 26ga. @ 28 KHz=0.79 500' 24 ga. @ 28 KHz=0.82 Change of +0.03dB loss. 1401' 19ga. @ 28 KHz=0.83 1630' 24 ga. @ 28 KHz=2.55 Change of +1.72dB loss. |
| MN |
Rochester ROCHMNRO |
06-12-2009 |
230103 |
82M1XM5 |
NO SAI (Terminals I University Center and I-851 30th Ave SE |
THIS JOB WILL CUT THESE 2 TERMINALS TO AN EXISTING FIBER FED PAIR GAIN SYSTEM THAT IS LOCATED AT THE COLLEGE. AT THE COMPLETION OF THIS JOB NO COPPER C.O. F-1 PAIRS WILL REMIAN AT THESE 2 TERMINALS. ALL EXISTING SERVICES WILL WORK AT THE COMPLETION OF THE JOB. THIS JOB IS DUE TO A ROAD RECONSTRUCTION PROJECT ON 4TH AVE SE. The before loss to terminal I-University Center is 37.86 dB at 28Khz which includes 5,813 feet of ANTW and 13,774 feet of ANMW (19.59 Kft). The after loss is .05 dB at 28Khz which includes 30 feet of ANMW cable (.03 Kft). The before loss to terminal I-851 30th Ave SE is 37.69 dB at 28Khz which includes 7,078 feet of ANTW, 345 feet of ANAW and 11,672 feet of ANMW (19.10 Kft). The after loss is 1.16 dB at 28Khz which includes 714 feet of ANMW cable (.71 Kft). |
| MN |
Rochester ROCHMNRO |
08-10-2009 |
213004 |
82M1XMD |
2300 Collegeview Rd SE |
THIS JOB WILL CUT ALL WORKING SERVICE TO THE EXISTING FIBER FED RT AT THIS LOCATION. THE WORK IS REQUIRED FOR THE 4TH ST SE ROAD RECONSTRUCTION PROJECT. ALL EXISTING SERVICES WILL CONTINUE TO WORK AT THE COMPLETION OF THIS JOB. No C.O. copper F-1 pairs will remain at X 2300 Collegeview Rd SE at the completion of this job. The before loss to X 2300 Collegeview Rd SE is 25.33 dB at 28Khz which includes 5,547 feet of ANTW and 7,001 feet of ANMW (12.55 Kft). The after loss is .02 dB at 28Khz which includes 100 feet of ANMW cable (.1 Kft). |
|
| Additional Information: |
Any customer premises equipment vendor/manufacturer or enhanced services provider desiring additional technical information in conjunction with this Disclosure can contact:
Georganne Weidenbach
Regulatory Compliance Manager
Georganne.Weidenbach@qwest.com
|
This Network Disclosure is available as a PDF download (file size: 144Kb). If you need to print Network Disclosures, the PDF file will give you more flexibility and a higher quality printout than will a Web page, which is designed to be viewed with a Web browser. If you need the Adobe Reader, you can download it for free from Adobe's Web site.