Qwest
Customer Service Search
Home - Residential - Small Business - Large Business - Partners - Wholesale
Network Disclosures


Network Disclosure Announcement #688

Short Term Public Notice Under Rule 51.333(a). Qwest's Internet address: http://www.qwest.com/disclosures.

Copper Retirements in Arizona, Colorado, Minnesota, New Mexico and Utah

First Implementation Date:

June 25, 2009

Original Date Posted:

April 22, 2009

Summary:

Copper Retirements are necessary to respond to various factors in the Outside Plant, including road construction, maintenance problems, and growth accommodation.  Replacement cables may be either copper or fiber.  Specific information will be provided with each disclosure.

Locations, Timing of Deployments & Interface Requirements:

The following gives additional details on the copper retirement(s):

STATE WIRE CENTER PLANNED COMPLETION OR RETIREMENT DATE DA (s) Job # FDI Address(es) Replacing
AZ Palominas PLMNAZMA 12-16-2009 410311 9212USB 10404 Dove Song Ln Qwest is replacing damaged cable placed in 1965. The existing leg of cable is a BHBS-25, the new cable will be ANMW-25. The dB loss @28KHz with the BHBS cable equals 4.800. The dB loss @28KHz with the new ANMW-25 equals 5.460. The terminal is at 3.16KFT from the XT, the XT is RT fed.
CO Granby GRNBCOMA 07-15-2009 N/A 9222VLU N/A Replacing 1600' of AFTW-600 with 1460' of ANMW-600
CO Pueblo West PUBLCO06 09-11-2009 310531 9222VQX 3208 Abarr REQUEST SHORT INTERVAL REPLACEMENT DUE TO DETERIORATED CABLE 3 SECTIONS: BEFORE: 3.341kf OF 24 GAUGE 50PR @28KHZ = 5.270 DB LOSS; AFTER: 3.384KF OF 24 GAUGE 50PR @28KHZ=5.340 DB LOSS: A DIFFERENCE OF 0.070DB LOSS, BEFORE: 1.745KF OF 24 GAUGE 200 PAIR CABLE @28KHZ = 2.730 DB LOSS; AFTER: 1.784KF OF 24 GAUGE 200 PAIR CABLE @28KHZ= 0.340 DB LOSS: A DIFFERNCE OF 0.060DB LOSS, BEFORE: 0.203KF OF 24 GAUGE 24 PAIR CABLE@ 28KHZ=0.340DB LOSS AFTER: 0.212KF OF 24 GAUGE @28KHZ = 0.360 DB LOSS: A DIFF OF 0.020 DB LOSS.
MN Glen Prairie EDPRMNGP 12-30-2009 310405 92M1YXU 16060 Pioneer Trl This is a cable replacement for road construction affecting 16050 Pioneer Trl. Old calculations= @ 28khz 9.730 db loss for 24 gauge cable @ 5.865 kf, new calculation= @ 28khz 9.830 db loss for 24 gauge cable @ 5.920 kf. New measurements reflect a slight addition of 24 gauge along the relocated route.
MN Rochester ROCHMNRO 07-23-2009 213002 now is 212901 92M1ZPH Was: X 1926 2nd ST SE, Now: R 1657 2nd ST SE Qwest is placing a new fiber fed RT and Sai at R 1657 2nd St SE to replace the copper feed and old Sai at 1926 2 St SE.All existing services will be supported with the new RT. No C.O. copper F-1 pairs will be available at X R 1657 2nd St SE at the completion of this job. The before loss to X 1926 2 St SE is 27.94 dB at 28Khz which includes 9,383 feet of ANTW, 2,318 feet of ANMW and 1,035 feet of ANAW cable (12.74 Kft). The after loss to X R 1657 2nd St SE is 12.22 dB at 28Khz which includes 3,145 feet of ANTW and 2,909 feet of ANMW cable (6.05 Kft).
MN St Cloud STCDMNTO 06-30-2009 122003 92M212A 5910 Ridgewood Rd JOB 92M212A REMOVES ALL COPPER FACILITIES FROM SAI 5910 RIDGEWOOD RD. CUSTOMERS WORKING ON COPPER WILL BE PLACED ON THE ISC303 DLC AT THE SAME LOCATION AS THE SAI.
MN Waseca WASCMNWA 09-30-2009 422502 92M1ZJ3 A1A THIS JOB WILL REPLACE 3990 FEET OF ANAW-25 AND 3990 FEET OF BHBH-16 WITH 3990 FEET OF ANAW-50. THE CABLES IS AS FOLLOWS: 19 GUAGE WITH A DB LOSS OF 2.620 AND 22 GUAGE WITH A DB LOSS OF 4.440 WITH AN ANAW-50 WITH A DB LOSS OF 4.440
MN West Saint Paul WSPLMNWS 06-30-2009 413603 92M1XVR 10400 Barnes Ave E Affected F2 count consists of: 10400B, 1251-1275 10400B, 601-625 10400B, 1376-1425 10400B, 576-600 F2 cable - 1.43 kFt of 22 gauge cable is being replaced by 1.95 kFt of 22 gauge cable, resulting in an increased dB loss of 0.16 dB. Work is done under order of MN-DOT SP1907-68, construction of Frontage Road on Hwy 52 ROW. This work does not consist of withdrawal of CLEC services.
NM Santa Fe North SNFENMNO 08-07-2009 210331 8251LJ3 15.1 County Rd 119 Qwest is removing all copper pairs at SAI X 15.1 County Rd 119. The existing services will be cut to a new Fiber fed RT/SAI and DSL counts at 2 County Rd 84G. Services requiring copper will no longer be supported. There are not any existing CLEC service types that can not be supported at the new RT. The longest F2 loop will be 14.2KF. Associated distribution job is 8251MNU.
UT Salt Lake West SLKCUTWE 06-25-2009 310502 H86A415 345 S 100 West The work begins at 1.72kf from the CO. The dB loss calculations for the individual copper cable sections are: Before: After: 26 1.800 24 1.720 22 0.180 24 0.750 =28 KHz 5.430 - 28 KHz 2.690 =2.74 Change 0f 2.690dB loss
Additional Information:

Any customer premises equipment vendor/manufacturer or enhanced services provider desiring additional technical information in conjunction with this Disclosure can contact:

Georganne Weidenbach
Regulatory Compliance Manager
Georganne.Weidenbach@qwest.com

This Network Disclosure is available as a PDF download (file size: 148Kb). If you need to print Network Disclosures, the PDF file will give you more flexibility and a higher quality printout than will a Web page, which is designed to be viewed with a Web browser. If you need the Adobe Reader, you can download it for free from Adobe's Web site.

Back to Top - Net Disclosure Main Page
Net Disclosures Listed Numerically

Questions regarding Network Disclosure information can be referred to the individual listed on the Disclosure Announcement or e-mail Dean Martineau, Qwest's Manager of Network Disclosures at a.martineau@qwest.com.