Network Disclosure Announcement #678
Copper Retirements in Minnesota, Montana, Nebraska, New Mexico, Utah and Washington
| First Implementation Date: |
March 31, 2009
|
| Original Date Posted: |
February 11, 2009
|
| Summary: |
Copper Retirements are necessary to respond to various factors in the Outside Plant, including road construction, maintenance problems, and growth accommodation. Replacement cables may be either copper or fiber. Specific information will be provided with each disclosure.
|
| Locations, Timing of Deployments & Interface Requirements: |
The following gives additional details on the copper retirement(s):
|
| STATE |
WIRE CENTER |
PLANNED COMPLETION OR RETIREMENT DATE |
DA (s) |
Job # |
FDI Address(es) |
Replacing |
| MN |
Rochester ROCHMNRO |
09-01-2009 |
120602 |
92M1XX7 |
901-11 |
Replacement of existing buried cable on road job. Before After 912' of 26 @ 28KHz = 2.2 1940' of 24ga @ 28KHz = 3.02 |
| MT |
Butte-Main BUTTMT09 |
06-26-2009 |
210260 |
9241AE6 |
CO FEED |
REPLACE DEFECTIVE EXIST'G UG 22GA LEAD FACILITES ON W PARK BTWN N MAIN AND N DAKOTA IN UPTOWN BUTTE, MT WITH AERIAL 24 GA FILLED CABLE. AT 49 W PARK: OLD LOOP = 0.280DB & 17.352 OHMS - NEW LOOP = 0.320DB & 24.068 OHMS. AT 9 N MAIN: OLD LOOP = 0.320DB & 24.642 OHMS - NEW LOOP = 0.470DB & 51.285 OHMS. NO HICAP OR SPECIAL CKTS AFFECTED - POTS ONLY. |
| NE |
Omaha 156 St OMAHNEHA |
07-21-2009 |
116502 |
91B16MS |
5000 S 187 Ave |
Replace 550' of ANAW-200 with 550' of ANMW-200 due to road construction. Old DB loss @ 1004 HZ= .280. New DB loss @ 1004 HZ=.340. A negative impact of .06 DB. Replace 236' of ALMW-100 with 236' of ANMW-100 due to road construction. Old DB loss @ 1004 HZ=.250. New DB loss @ 1004 HZ=.250. No change. |
| NE |
Omaha 84th St OMAHNE84 |
09-02-2009 |
415104 |
92B16LV |
108 and Q St |
The following working circuits are derived 18.140 Kf from C.O. The dB loss calculations for the this section is: F2 pairs UC, 201-300 The existing sections 868' of 24 GA, 41' of 26 GA and 944' of 22 GA are being replaced by 1,732' of 24 GA, 41' of 26 GA and 104' of 22 GA OLD F2 route of 1.853 KF @ 28KHz=2.460dB & 1004Hz=0.650dB NEW F2 route of 1.877 KF @ 28KHz=2.910dB & 1004Hz=0.740dB Change of +0.45dB loss @ 28KHz & +0.090dB loss @ 1004KHzThe working circuits are derived 18.140 Kf from the C.O. |
| NE |
Tekamah TKMHNENW |
03-31-2009 |
215102 |
82B16K5 |
F1 Feed to the rural for distribution |
BEFORE:1160' OF ALAW-100 & 142' OF AFAW-100@28KHZ=38.80 AFTER: 985' OF ALAW-100 & 675' OF ANAW-100@28KHZ=39.25. CHANGE OF +0.45DB LOSS. THE BRIDGE AT CO RD 44 & CO RD GH WILL BE REBUILT AND THE EXISTING CABLE IS ATTACHED TO THE BRIDGE. IT IS PLANNED TO BORE A NEW CABLE UNDER THE DIVERSION DITCH AND BE OUT OF CONSTRUCTION CONFLICTS. THIS WILL ENSURE THAT THE CABLE WILL NOT BE DAMAGED. BRIDGE CONSTRUCTION IS SCHEDULED FOR 4/1/09. |
| NM |
Pena Blanca PNBLNMMA |
05-08-2009 |
116701 |
8251NNV |
N/A |
REPLACE 2020FT OF BHAU-100 WITH 2200FT OF ANAW-100 |
| NM |
Rio Rancho ALBQNMRR |
11-30-2009 |
116611 |
7251G4X |
1653 Abrazo Rd NE |
This job will be cutting over customers from Direct CO feed to new RT based count from the X-Box, 9 POTS and 3 DSL workers. All copper has been removed from X-Box and has been replaced with count from a Remote Terminal. No CLECS circuits exist today. |
| UT |
Logan LOGNUTMA |
04-07-2009 |
214203 |
H96A009 |
SAI |
Qwest will remove 158' of BKTA-50 and 153' of BKTA-50. Qwest will replace these cables with 396' and 342' of ANMW-50. This results in a change of +0.230 dB loss and +0.170 dB loss @ 28 KHz for the two legs of cable. Terminals affected are 825 n 600 east, 519 e 800 north, 838 n 500 east and 581 e 800 north. A "short interval" is requested. |
| WA |
Sumner SMNRWA01 |
04-30-2009 |
4210101 |
92W27ZW |
N/A |
QWEST WILL REMOVE 2 SECTIONS OF AERIAL CABLE AND PLACE NEW AERIAL CABLE DUE TO SIDEWALK PROJECT. REMOVE OLD 24 GAUGE CABLE AND PLACED NEW 24 GAUGE CABLE. BEFORE = 3.205KF AFTER = 3.220KF . BEFORE dB LOSS=6.80 AFTER dB LOSS = 6.86 |
|
| Additional Information: |
Any customer premises equipment vendor/manufacturer or enhanced services provider desiring additional technical information in conjunction with this Disclosure can contact:
Georganne Weidenbach
Regulatory Compliance Manager
Georganne.Weidenbach@qwest.com
|
This Network Disclosure is available as a PDF download (file size: 134Kb). If you need to print Network Disclosures, the PDF file will give you more flexibility and a higher quality printout than will a Web page, which is designed to be viewed with a Web browser. If you need the Adobe Reader, you can download it for free from Adobe's Web site.
Back to Top - Net Disclosure Main Page
Net Disclosures Listed Numerically
Questions regarding Network Disclosure information can be referred to the individual listed on the Disclosure Announcement or e-mail Dean Martineau, Qwest's Manager of Network Disclosures at a.martineau@qwest.com.
|