Network Disclosure Announcement #651
Copper Retirements in Arizona, Colorado, Iowa, Minnesota, New Mexico and Washington
| First Implementation Date: |
August 13, 2008
|
| Original Date Posted: |
June 12, 2008
|
| Summary: |
Copper Retirements are necessary to respond to various factors in the Outside Plant, including road construction, maintenance problems, and growth accommodation. Replacement cables may be either copper or fiber. Specific information will be provided with each disclosure.
|
| Locations, Timing of Deployments & Interface Requirements: |
The following gives additional details on the copper retirement(s):
|
| STATE |
WIRE CENTER |
PLANNED COMPLETION OR RETIREMENT DATE |
DA (s) |
Job # |
FDI Address(es) |
Replacing |
| AZ |
Cottonwood South CTWDAZSO |
08-15-2008 |
110131 |
8212LD5 |
2597 S Pleasant Dr |
Replace 933' of bhah-50@28khz=1.65 with 995' anmw-50@28khz=1.72 a change of +0.07db loss. |
| CO |
Evergreen EVRGCOMA |
09-30-08 |
211731 |
H82A563 |
25018 Stanley Park Rd |
504' of BKMH is being section cut and replaced with 676' of ANMW. This adds 172' of 24ga copper for a 0.06 added dB loss. |
| CO |
Monument MNMTCOMA |
08-14-2008 |
110532 |
82227WH |
131TS |
This job requires a total of six spans of aerial cable be buried to accomodate the removal of power poles along third street between Beacon Lite Rd. and Front St totaling 739 feet of buried cable. Before Job Loop length = 1350 Loop resistance = 59ohms Loop loss = 52 db @ 1004hz After Job Loop length = 1374 feet Loop resistance = 60ohms Loop loss = 53 db @ 1004hz |
| CO |
Pikeview CLSPCOPV |
08-16-2008 |
310633 |
8222LD1 |
201 Elmwood Dr |
Section one: Before: 659' 24 ga and 707' of 22 ga = 1.79 DB loss at 28 KHz After: 1.363 KF of 24 ga = 2.15 DB loss at 28 KHz Negative 0.36 DB loss |
| CO |
Pueblo PUBLCOMA |
09-30-2008 |
413321 |
8222LPP |
350 n Monuments Av. |
QWEST REPLACING EXISTING COPPER CABLE PLACED IN 1964WITH NEW COPPER CABLES: 350MO,476-500 WITH NEW CABLE WITH NEW COUNT OF 350MO,301-350 ;BEFORE:0.770 DB LOSS. AFTER DB LOSS 0.800 DB LOSS. ALSO, REMOVING EXISTING CABLE PLACED IN 1961: 350MO,401-500, REPLACING FEED WITH EXISTING CABLE NEW COUNT: 350MO,301-350 THIS SECTION BEFORE: 0.650 DB LOSS, AFTER CUTOVER TO EXISTING CABLE 0.720 DB LOSS |
| IA |
Des Moines Ashworth DESMIAAW |
03-01-2009 |
140503 |
82C1CBS |
8571 Clark |
Qwest is rerouting buried cables in conflict with a road project. F2 cable - 12.533Kft of 24 gauge is being replaced by 12.597Kft of 24 gauge. The loss is increased by +.030dB at 1004 Hz. |
| IA |
Winterset WNTRIACO |
10-01-2008 |
120401 |
82C1CLU |
2270 Holliwell Bridge Rd |
Job will CO copper pairs at X 2270 Holliwell Bridge Rd to Pair Gain. Pairs to be cut - 8: 7,9,13-15,19,23. F1 loops will be reduced from approximately 22 kf to 0.03 kf. All POTS, no unbundled or special circuits involved. |
| MN |
Oak Grove OKGVMNOG |
08-29-2008 |
480405 |
82M1U5L |
17498 Nowthen Blvd NW |
REPLACEMENT OF COPPER FACILITIES ALONG VARIOLITE ST NW , 2500' OF 19GA AND 22GA, WILL BE REPLACED WITH 24GA CABLE. ALL OTHER CABLE WILL REMAIN 19 AND 22GA. . |
| MN |
Park Row NSPLMNPR |
10-13-2008 |
110505 |
82M1U6R |
2553 13 Av NE |
Qwest is moving the existing SAI from X 2553 13 Av NE to SAI 2520 12th Ave E. The feeder distance will actually be less (from 7.4 KF to 7.0 KF). The F2 distance will increase. The existing total loop length to Terminal R 2695 is 10.12 KF with a dB loss of 22.09 @ 28 KHz. The after total loop length to Terminal R 2695 is 10.099 KF with a dB loss of 22.15 @ 28 KHz. The difference is +0.06 dB. |
| NM |
Artesia ARTSNMMA |
08-13-2008 |
210701 |
H75A040 |
2 rl4 |
This job transfers workers from the 1,1051-1075 to 906,126-150. The total loop loss at 1004 Hz will increase from 1.980 dB to 2.960 dB. The transfer is required due to construction of a new railroad spur. The time frame on the railroad job requires an exception to the 95 day retirement interval. |
| NM |
Santa Fe North SNFENMNO |
10-30-2008 |
210191 |
8251M1P |
1 Nambe |
The work begins 17.231kft from the existing CO a (slc-96) is only 8.387 from the X 1 Nambe. The db loss calculations for the copper cable sections are: BEFORE: 1435' XXAX-18 & 929' XXAX-6 @ 28KHZ a total of = 2.520db's AFTER: 2750' ANMW-25 @ 28khz=4.680db's Change of 2.16db loss. |
| WA |
Orchards ORCHWA01 |
06-05-2009 |
412031 |
H8WA481 |
No SAI CO, Fed Copper |
We are changing the entire LMU for terminal 8917-11 NE Fourth Plain. The original CO fed loop is now being changed so this terminal will feed from the SAI 3720 NE 86th. Before: loop length=11950 ft total bridge=810 ft loop resistance=612 ohms loop current=35 ma loss @ 1004 hz=4.17 db After: loop length=12800 ft total bridge tap = 0 ft loop resistance=669 ohms loop current=34 ma loss @ 1004 hz=4.47 db |
|
| Additional Information: |
Any customer premises equipment vendor/manufacturer or enhanced services provider desiring additional technical information in conjunction with this Disclosure can contact:
Georganne Weidenbach
Regulatory Compliance Manager
Georganne.Weidenbach@qwest.com
|
This Network Disclosure is available as a PDF download (file size: 112Kb). If you need to print Network Disclosures, the PDF file will give you more flexibility and a higher quality printout than will a Web page, which is designed to be viewed with a Web browser. If you need the Adobe Reader, you can download it for free from Adobe's Web site.
Back to Top - Net Disclosure Main Page
Net Disclosures Listed Numerically