Network Disclosure Announcement #597
Copper Retirements in Arizona, Colorado, Idaho, Minnesota, Montana, Nebraska, New Mexico, North Dakota, Oregon, Washington, Wyoming
| First Implementation Date: |
February 15, 2007
|
| Original Date Posted: |
February 16, 2007
|
| Summary: |
Copper Retirements are necessary to respond to various factors in the Outside Plant, including road construction, maintenance problems, and growth accommodation. Replacement cables may be either copper or fiber. Specific information will be provided with each disclosure.
|
| Locations, Timing of Deployments & Interface Requirements: |
The following gives additional details on the copper retirement(s):
|
| STATE |
WIRE CENTER |
PLANNED COMPLETION OR RETIREMENT DATE |
DA (s) |
Job # |
FDI Address(es) |
Replacing |
| AZ |
Cave Creek CVCKAZMA |
03-31-2007 |
210371 |
H71A030 |
37228 N Tranquil Trail |
THIS JOB WILL REPLACE EXISTING COPPER CABLE (416' OF 24 GAUGE WITH A DB LOSS OF 0.760db) WITH 438' OF 24 GAUGE (0.8DB). |
| AZ |
Phoenix Northwest PHNXAZNW |
12-01-2007 |
318612 318671 |
H61A012 |
1853 W Colter St, 5005 N 19th Ave |
Qwest is removing the SAI at 5005 N. 19 Av and relocating the SAI at 1853 W. Colter St. Qwest is also relocating the the feeder and backbone distribution cables along 19th Avenue between Camelback Road and Missouri Avenue. Thirty-one (31) distribution terminals (with a total of 225 working lines), currently working out of SAI 5005 N 19 Av will be cut to SAI 1853 W. Colter St. The cables affected are all 24 gauge and will remain the same gauge. Qwest will replace 1803 feet (1.80Kft) of BKMH-900 with 1817 feet (1.82Kft) of ANMW-1800 feeder cable. Also, 334 feet (0.33Kft) ANMW-200 with 746 feet (0.75Kft.) ANMW-200 distribution cable, 821 feet (0.82Kft.) ANMW-100 with 1147 feet (1.15Kft.) ANMW-100 distribution cable, and 600 feet (0.60Kft) ANMW-50 with 636 feet (0.64Kft) ANMW-50 distribution cable. The eighty (80) affected terminals are: I UDC 5201 N 19 AV, WF 5130 N 19 AV, 5238 N 18 DR, I 5201 N 19 AV, W 1815-E W COLTER ST, W 1815-F W COLTER ST, WF 1815-C W COLTER ST, 5254 18 DR, 5253 N 18 DR, F 5109 N 19 AV, F 5045 N 19 AV, 5237 N 18 DR, WF 1815-D W COLTER ST, WT 5119 N 19 AV, 5222 N 18 DR, W UDC 1815-C W COLTER ST, W 1815-B W COLTER ST, W 1815-A W COLTER ST, 5204 N 18 DR, I 5124 N 19 AV, R 5124 N 19 AV, WF 1830 W COLTER ST, I 5151 N 19 AV, I 5013 N 19 AV, F 5005A N 19 AV, 5221 N 18 DR, 5203 N 18 DR, I 1840-2 W CAMELBACK RD, I 1840-1 W CAMELBACK RD, I 5033 N 19 AV, I 5039 N 19 AV, R 5219 N 20 AV, R 5205 N 20 AV, R 5345 N 20 AV, R 1933 W DENTON LN, R 1911 W DENTON LN, I 5336 N 19 AV, R 1931 W MISSOURI AV, R 1901 W DENTON LN, R 1917 W DENTON LN, R 1931 W DENTON LN, R 5425 N 19 AV, I 1737 W MISSOURI AV, R 2001 W VERMONT AV, R 2001 W MISSOURI AV, R 2021 W VERMONT AV, R 2015 W VERMONT AV, R 2043 W VERMONT AV, R 2035 W VERMONT AV, R 5331 N 20 AV, R 5323 N 20 AV, I 5301 N 19TH AVE, I UDC 1815 W MISSOURI AV, R 1925 W MISSOURI AV, R 1913 W MISSOURI AV, R 5241 N 20 AV, R 5233 N 20 AV, I 1815-1 W MISSOURI AV, R 1873 W MISSOURI AV, R 1939 W VERMONT AV, R 1929 W VERMONT AV, I 1815-2 W MISSOURI AV, WF 5323-25 N 19 AV, WF 5323-11 N 19 AV, R 1919 W VERMONT AV, WF 5323-6 N 19 AV, WF 5323-31 N 19 AV, R 1907 W VERMONT AV, R 1911 W GEORGIA AV, R 1903 W GRORGIA AV, R 1931 W GEORGIA AV, R 1923 W GEORGIA AV, W UDC 1933 W OREGON AV, I UDC 1908 W COLTER ST, I 5225 N 19 AV, F 5301 N 19 AV, R 1913 W OREGON AV, R 1931 W OREGON AV, R1901 W OREGON AV, AND F 1885 W COLTER ST. The facilities are being relocated to eliminate conflicts along 19th Avenue with the road widening and improvements associated with construction of the new Phoenix Light Rail system which is now under construction . |
| AZ |
Prescott PRSCAZMA |
05-31-2007 |
116531 |
C61A237 |
6449 Wilkinson Dr |
THIS JOB REPLACES 3.194KF OF 22 GAUGE AND .373KF OF 24 GAUGE WITH 4.52KF OF 24 GAUGE CABLE, WITH AN INCREASED DB LOSS OF +5.32DB. |
| CO |
Carbondale CRDLCOMA |
06-01-2007 |
310531 |
C72A032 |
2 Harris Drive |
This job is located in River Valley Ranch in Carbondale, Colorado. This job will abandon 250' of ANMW-100 & ANMW-25 and remove six USW-8, PTX-6. Retirements on this job are as follows; BEFORE 250' of ANMW-100 @ 28KHz = 0.434 AFTER 560' of ANMW-50 @ 28KHz = 0.973, which equals a dB loss of +0.539. BEFORE 250' of ANMW-25 @ 28KHz = 0.434 AFTER 330' of ANMW-25 @ 28KHz = 0.573, which equals a dB loss of +0.139. |
| CO |
Ft Follins FTCLCOMA |
05-01-2007 |
416813 NEW 416861 OLD |
6221PG6 |
841 N Briarwood Dr |
The existing straight feed will retire and be removed. The service will be cut over to a existing x box and new copper. This CHANGES A DIRECT FEED CABLE INTO A SAI FED CABLE AND ADDS 1.9 KF TO THE LOOP. The BEFORE LOSS IS 29.24 DB AT 28KH AND 893.7OHMS THE AFTER LOSS IS 32.6 DB AT 28KH AND 992.2 OHMS BEFORE LENGTH IS 18.6 KKF AFTER IS 20.47 KF 1.9 KF 24 GA ADDED |
| CO |
Grand Junction GDJTCOMA |
03-02-2007 |
312731 |
7121U5C |
2676 B _ RD |
This job will replace and existing 926' aerial section of BKMP-100 that was torn down. The existing cable will be replaced with 968' of aerial ANMW-100. The project is located 17.661Kf from the CO. dB loss is as follows: Before 1.48dB @ 28KHz and after 1.55dB @ 28 KHz., and increase of .07dB. |
| CO |
Gunbarrel BLDRCOGB |
07-01-2007 |
110224 |
6221PEB |
4990 Idylwild Trail |
REPLACEMENT OF 551' BHAA-2,182' ALMW-100,551' BHAA-100PR CABLES WITH 642' ANMW-200 AND 659' ANMW-100 . WORK IS FROM PED 6831 FRYING PAN RD TO PED 6931 ROARING FORK TRAIL. |
| CO |
Littleton LTTNCOMA |
03-15-2007 |
418831 |
C72A046 |
201 W Mineral |
Qwest is replacing existing cable for partial demo of existing building 151 Mineral Av. Terminals affected 151 Mineral #-2,-3 & -4. Count - 201WM, 1-300, TPR 418831. A 785' 24 ga section (.44dB) will be replaced with a 1141'-24 ga section (.57 dB), adding .13dB. Short notification required. |
| CO |
Pikeview CLSPCOPV |
05-25-2007 |
417232 417221 |
6224961 |
5723 Mark Baling Blvd and 5322 N Cascade Ave |
Qwest is removing all the copper pairs at X 5723 Mark Dabling Blvd and X 5322 N Cascade Ave. All existing Qwest and CLEC circuits will continue to be served at this location. They will both be fed from the existing fiber fed pair gain system. |
| ID |
Riverside RVSDIDMA |
04-30-2007 |
350400 |
623E430 |
1052 S 100 West to be changed to 90 S 1050 West |
No CLEC facilities were identified in this DA. The job will move the cross connect 260' to the north to improve visibility at the intersection per Bingham County request. Cables between existing SAI and branch splice will be retired. |
| ID |
Twin Falls TWFLIDMA |
03-02-2007 |
414202 |
H63A009 |
900 Filer Ave W |
REPLACE 28' LOOP OF BKTH-50 WITH 68' LOOP OF ANMW-50. |
| MN |
Detroit Lakes DTLKMNDL |
05-15-2007 |
2910802 |
72M1G6H |
CO RD 116 |
DA 290802,X CO RD 116, F1@28KHZ .030 DB LOSS NO CHG F2 @ 28KHZ 1.870 DB before and 2.360 DB after. RETIREMENTS ARE AS FOLLOWS 1,318' 22 GUAGE 303' 24 GUAGE PLACEMENTS ARE AS FOLLOWS 1,504 24 GUAGE All work due to MNDOT rebuilding 1,500' of Co Rd 54 & HWY 10. |
| MN |
Park Rapids PKRPMNPR |
09-04-2007 |
411002 411202 |
72M1G14 |
607 W 1 ST X 500/1 |
This combining the two x-boxes down to one which shortens the F1 length & lengthens the F2. 5,312' of 19ga. will be replaced with 24ga. |
| MN |
Rochester ROCHMNRO |
03-16-2007 |
210202 |
C6MA253 |
None |
Before After 25 feet ANMW-100 @ 28 KHz = .040 138 feet ANMW-50 @ 28 KHz = .230 Change of +.190 dB loss.. |
| MT |
Billings West BLNGMTWE |
03-15-2007 |
310261 |
C74A002 |
3128 Gabel Rd |
RELOCATE CABLE: BEFORE:406'ANMW-400 @ 28KHZ=.670 AFTER:900' ANMW-400 @ 28KHz= 1.440 Change of .770dB loss. |
| MT |
Darby DRBYMTMA |
04-15-2007 |
321141 |
71415EZ |
N/A |
Qwest is removing temporary cable placed to eliminate conflict with state highway project. F2 cable - 210' of 22 gauge will be replaced by 380' of 22 ga. The loss is +.0.18 dB. |
| ND |
Bismarck BSMRNDBC |
07-01-2007 |
170203 170202 |
72F13TD |
3021 Hamilton ST, 2814 Colorado Dr. |
THIS AUTHORITY WILL REFEED 2 SAI'S THAT ARE PRESENTLY PARTIALY FED FROM C.O COPPER.THE NEW FEED WILL BE 100% FROM A FIBER FED RT.THE EXISTING COPPER FEED(20,000 FEET OF ANMW-600 PAIRS CABLES) WILL BE ABANDONED TO CLEAR THE WORK AREA FOR A STATE OF NORTH DAKOTA ROAD RECONSTRUCTION PROJECT.NO COPPER FEED WILL EXIST AT THESE SAI'S AFTER COMPLETION OF THE JOB.NO EXISTING CLEC CUSTOMERS EXIST AT THESE SAI'S TODAY.EXISTING COPPER LOSS IS 41.230@28KHZ.THE NEW LOSS WILL BE 4.510@28KHZ.THE F2 PORTION OF THIS JOB WILL BE LIKE FOR LIKE. |
| ND |
Bismarck BSMRNDBC |
07-05-2007 |
370702 370704 |
72F13BP |
7501 Signal, 7500 University Dr |
PLACING COPPER DISTRIBUTION FACILITIES ALONG ND HWY 1804; LOCATED APPROXIMATELY 41.6 KFT SOUTH OF THE BISMARCK CO. WORK WILL CONSIST OF PLACING 1148' OF ANMW-900, 1790' OF ANMW-300, 3393' OF ANMW-200, 5730' OF ANMW-100, 1926' OF ANMW-50, 2654' OF ANMW-25, 1 - QWEST-12, 2 - QWEST-8, 17 - QWEST-6 CLOSURES, 6 - PTX-12, 9 - PTX-6 TERMINAL BLOCKS, 2015' OF 6X22 & 4801' OF 3X22 BSW. THE DB LOSS CALCULATIONS FOR THE COPPER CABLE SECTIONS ARE: BEFORE: AFTER: 666' AFTW-600 @ 28 KHZ = 1.6DB 1148' ANMW-900 @ 28 KHZ = 1.82DB CHANGE OF +.22DB . 2351' ALAW-100 @ 28 KHZ = 2.5DB 2253' ANMW-200 @ 28 KHZ = 3.51DB CHANGE OF +1.01DB . 2223'BHBH-50 @ 28 KHZ = 1.36DB 2253' ANMW-200 @ 28 KHZ = 3.51DB CHANGE OF +2.15DB . 1417' ANMW-100 @ 28 KHZ = 1.49DB 1417' ANMW-100 @ 28 KHZ = 1.49DB CHANGE OF 0DB . 1086' BHBH-100 @ 28 KHZ = .64DB 1035' ANMW-100 @ 28 KHZ = 1.65DB CHANGE OF +1.01DB . 2338' BHBH-50 @ 28 KHZ = 1.44DB 2872' ANMW-100 @ 28 KHZ = 4.49DB CHANGE OF +3.05DB. 6405' BHBH-25 @ 28 KHZ = 4.43DB 6270' ANMW-25 @ 28 KHZ = 9.67DB CHANGE OF +5.24DB. 3278' BHBH-100 @ 28 KHZ = 2.09DB 3133' ANMW-100 @ 28 KHZ = 4.92DB CHANGE OF +2.97DB. 402' ALAW-50 @ 28 KHZ = .43DB 402' ANMW-100 @ 28 KHZ = .66DB CHANGE OF +.23DB. 1707' ALAW-100 @ 28 KHZ = 1.8DB 1791' ANMW-100 @ 28 KHZ = 2.8DB CHANGE OF +1DB. 955' LBW-11 @ 28 KHZ = .56DB 1165' ANMW-25 @ 28 KHZ = 1.85DB CHANGE OF +1.29DB. |
| NE |
Ainsworth ANWONENW |
05-21-2007 |
410303 |
72B13YA |
E1S |
Old F2 route of .917KF @ 28KHZ=.54db. New F2 route of 1.049KF @ 28KHZ=.62db. Change of +.08db. Retire buried copper facilities between tea 356-3 & LP#16 |
| NE |
Axtell AXTLNENW |
04-27-2007 |
410102 |
62BC342 |
N/A |
This job will replace 318 ft of BHBH-25 with dB loiss of .180 @28KHz with 506 ft of ANMW-25 with a dB loss of .830dB @28KHz.. the difference will be +.650 loss. |
| NM |
Albq North ALBQNMNO |
06-01-2007 |
311302 |
625K809 |
1201 La Poblana Rd NW |
This job will replace aerial distribution cable from 1201 La Poblana Rd NW westward to 2613 20th St NW using 4325ft of existing Qwest strand. The dB loss calculations for the individual copper cable sections are: Before-1252'BHBA-25 @28kHz=0.74 & After-550'ANMW-25 &600'ANMW-50 @28KhZ=1.83. Change of +1.09dB loss.Before-549'BHAA-50 @28kHz=0.59 & After-650'ANMW-50 @28kHz=1.06. Change of +0.47dB loss. Before- 520'BHAA-150 @28kHz=0.56 & After- 580'ANMW-100 @28kHz=0.95. Change of +0.39dB loss. Before- 1468'BKMA-200 @28kHz=2.31 & After- 1500'ANMW-200 @28kHz=2.36. Change of +0.05dB loss . Before- 668'BKMH-400 @28kHz=1.08 & After- 725'ANMW-400 @28kHz=1.17. Change of +0.09dB loss. |
| NM |
Albq Southwest ALBQNMSW |
02-20-2007 |
211201 |
H75A007 |
149 2 SW |
This work is necessary to relocate a buried 50 pair cable during construction of a County waterline at 2nd St NW, South of Lagunitas Ln SW. The work entails digging two splice pits 250' apart and splicing 350' of cable. The extra 100' of cable will allow the contractor (RMCI, Inc) to manipulate the cable during a boring and vault placing activity. Upon completion of their work RMCI will place the cable in their trench supervised by a Qwest CI, and the extra 100' will be trimmed out. The work begins at 25.70Kft from the Albuquerque Southwest Central Office. The dB loss calculations for these copper sections are: Before AFTER 250' of AJAW-50 @ 28KHz = 0.300 250' ANMW-50 @ 28KHz = 0.460 Change of +0.160dB loss. |
| NM |
Albq Southwest ALBQNMSW |
02-20-2007 |
216601 |
H75H006 |
5601 University Blvd SE |
This job places 1160' of anmw-50, 170' of anmw-200, removes 1000' of anmw-50 The work begins at 2.70Kft from the RT 5601 University Blvd SE. The dB loss calculations for these copper sections are: Before AFTER 1000' of ANMW-50 @ 28KHz = 1.760 1150' ANMW-50 @ 28KHz = 2.009 Change of +0.249dB . |
| OR |
Bend BENDOR24 |
03-15-2007 |
431712 |
72R1IO1 |
100 NW Putman Rd |
This job will replace 200' of buried 22 Ga cable with a new section of 250' of buried 24 Ga. cable. This will make a difference of an additional +0.2 dB @ 28 KHz to the loop. This work has to be done prior to the 95 day RFS window. No existing CLEC circuits were found for this section.. |
| OR |
Bend BENDOR24 |
02-27-2007 |
414911 |
H7RA017 |
915 NW Brooks St |
There are no CLEC circuits working in the cable section being replaced. 20' of 22 Ga cable ( 0.02 dB) will be replaced with 50' of 24 Ga cable (0.08 dB). This will reuslt in a negative impact of -0.06 dB in this section.. |
| OR |
Klamath Falls FLFLOR54 |
02-15-2007 |
335011 |
72RLIOO |
3300 Joe Wright Rd |
No CLEC circuits are involved. This project will replace 546' of bhaa 51 with anmw-50 damaged as a result of a car-pole crash on 2/2/07. |
| OR |
North Plains NPLNOR62 |
03-05-2007 |
221201 |
72R1IRG |
30-232-1 NW Bacona Rd |
Relocate 300 feet of ANAW-25 cable currently attached to the Greener Rd bridge across Dairy Creek. Washington County is replacing the bridge and the cable must be relocated. The cable will be moved to an existing pole line by placing 410 feet of ANAW-25. |
| OR |
Springfield SPFDOR01 |
03-15-2007 |
214221 219811 213405 219902 |
72R1IOT |
36625 Wheeler Rd, 83801 Mill Rd, 38000 Jasper-Lowell Rd |
Replace 2.7 KF of existing 19 gauge with 22 gauge. The section being replaced is on 42ND Street between Main and Glacier. The City of Springfield's 42ND St road widening job will make saving the existing 19 ga cable impossible. |
| WA |
Aberdeen ABRDWA01 |
04-15-2007 |
322102 |
72W1MSU |
601 3 D St |
Replacing 26-GA distribution cable with new 24-GA cable in Cosmopolis, WA. The longest loop impacted results in a 1.98db change. (Before: 1.47KF 26GA @ 28KHz = 3.410db. After: 3.412KF @ 28KHz = 5.390db). Requesting a short term notification; the existing cable is deteriorating and needs to be replaced. |
| WA |
Fairfax SPKNWAFA |
05-31-2007 |
1304 |
72W1LIG |
1302 W Dalke Av |
Qwest is replacing 565' of damaged 24-gauge lead cable with 570' of 24-gauge copper cable. There will be an estimated increase of dB loss of 0.01 at 28 kHz. |
| WA |
Fort Lewis TACMWAFL |
05-21-2007 |
110411 |
72W1MTH |
6000 Hillside Dr |
Demolition of existing houses in the" Old Hiilside Neighborhood" residential homes. Qwest to abandon & remove all copper structure currently served by cable count 6000H, 1001-1250. There are currently 5 lines working, one disconnecting 02-17-07. Four lines are temporary for construction trailers working out of terminal 6015 Fort Lewis, to be removed @ the end of project. |
| WA |
Kent Meridian KENTWAME |
06-30-2007 |
210503 |
71W1LWM |
17002 SE 256TH |
QWEST is relocating direct buried cable for a Road Improvement for the City of Covington Phase 4 along se 256th east of 164th ave se to 170th ave se. Changing F2 distribtuion count of 17002-256, 551-600 from 1.009 kt of ANMW-100 to 0.710 kt of ANMW-100,0.160 kt of ANMW-400,0.270 kt of ANMW-600 with a +0.20db loss difference. No impact on existing circuits. Changing F2 distribution count of 17002-256,226-250 from 0.184KT of ANMW-50 to 0.220 of ANMW-900 with a +0.060db loss difference. No impact on existing circuits. |
| WA |
Kent Ulrich KENTWA01 |
03-31-2007 |
230405 |
62W |
11062 SE 196TH |
Qwest is rearranging facilities in conflict with a King County Road Project at the intersection of SE 192nd and 108th AV SE. Rearrangements, placing and removals, will add approxamently .341 kf to the F_1 loop. This is an negative impact of + 1.18 Db @196 KHz to the overal loop. Existing SAI terminal X 11062 SE 192D is 27.39 kf from the CO. New LMU will be 27.73 Kf from the CO. Terminal is fed with 35% copper CO pairs and 65% pairgain. Placing TOTAL 0.747 LENGTH (KF) GAUGE LENGTH in (KF) 24 0.380 F1* ANMW-900 24 0.367 F1* ANMW-600 LOSS (dB) 28 KHz 1.210 36 KHz 1.230 40 KHz 1.240 196 KHz 2.210 772 KHz 4.210 DSL 2.316 1004 Hz 0.400 RESISTANCE Ohms 39.068 REMOVING Section TOTAL 0.406 LENGTH (KF) GAUGE LENGTH in (KF) 24 0.225 BKMA-600 24 0.061 BKMA-600 22 0.120 BHAA-600 LOSS (dB) 196 KHz 1.030 RESISTANCE Ohms 18.905 A difference of +1.18 Db @196 KHz REMOVING Section TOTAL 0.409 LENGTH (KF) GAUGE LENGTH in (KF) 24 0.225 F1* BKMA-600 24 0.075 F1* ANMW-600 24 0.109 F1* ANMW-600 LOSS (dB) 196 KHz 1.110 RESISTANCE Ohms 21.390 A difference of +1.10 Db @196 KHz |
| WA |
Renton RNTNWA01 |
03-31-2007 |
355004 |
62W |
11062 SE 196TH |
Qwest is rearranging facilities that are in conflict with a King County Road Project at the intersection of SE 192nd and 108th AV SE. Rearrangements, placing and removals will add approxamently .341 kf to the F_1 loop. This is an negative impact of + 1.18 Db @196 KHz to the overal loop. New LMU will be 24.04 Kf from the CO. Placing TOTAL 0.747 LENGTH (KF) GAUGE LENGTH in (KF) 24 0.380 F1* ANMW-900 24 0.367 F1* ANMW-600 LOSS (dB) 28 KHz 1.210 36 KHz 1.230 40 KHz 1.240 196 KHz 2.210 772 KHz 4.210 DSL 2.316 1004 Hz 0.400 RESISTANCE Ohms 39.068 REMOVING Section TOTAL 0.406 LENGTH (KF) GAUGE LENGTH in (KF) 24 0.225 BKMA-600 24 0.061 BKMA-600 22 0.120 BHAA-600 LOSS (dB) 196 KHz 1.030 RESISTANCE Ohms 18.905 A difference of +1.18 Db @196 KHz REMOVING Section TOTAL 0.409 LENGTH (KF) GAUGE LENGTH in (KF) 24 0.225 F1* BKMA-600 24 0.075 F1* ANMW-600 24 0.109 F1* ANMW-600 LOSS (dB) 196 KHz 1.110 RESISTANCE Ohms 21.390 A difference of +1.10 Db @196 KHz |
| WA |
Spokane Whitworth SPKNWAWH |
04-29-2007 |
121001 |
62WT921 |
13129 N Mill Rd |
This job replaces 2.31kf of 22 guage cable with 2.85kf of 22 guage resulting in 1.2 additional dB loss. This job is a public requirement, exsiting route travels through land being developed. |
| WA |
Sunnyslope SNYSWA01 |
05-18-2007 |
401701 |
72W1LJR |
8701 State Hy 3 SW |
Job will place new Fiber fed Litespan cabinet and turn up exisitng fiber abandoning exisitng buried copper cables in place. LMU = Before: 22ga = 1.1Kf, 24ga = 5.2Kf, 26ga = 6.8Kf Loss @ 28KHz = 26.58. There are no CLEC circuits in this cable. After: 24ga = .020Kf Loss @ 28KHz = .030 |
| WY |
Jackson JSCNWYMA |
04-18-2007 |
414501 |
C77A004 |
3528 N Lake Creek Dr |
Replace 86' of ALMW-200 with 107' of ANMW-200. Existing cable is in conflict with the Berry Patch bridge replacement and needs to be rerouted |
|
| Additional Information: |
Any customer premises equipment vendor/manufacturer or enhanced services provider desiring additional technical information in conjunction with this Disclosure can contact:
Georganne Weidenbach
Regulatory Compliance Manager
Georganne.Weidenbach@qwest.com
|
This Network Disclosure is available as a PDF download (file size: 112Kb). If you need to print Network Disclosures, the PDF file will give you more flexibility and a higher quality printout than will a Web page, which is designed to be viewed with a Web browser. If you need the Adobe Reader, you can download it for free from Adobe's Web site.
Back to Top - Net Disclosure Main Page
Net Disclosures Listed Numerically
Questions regarding Network Disclosure information can be referred to the individual listed on the Disclosure Announcement or e-mail Dean Martineau, Qwest's Manager of Network Disclosures at a.martineau@qwest.com.
|