Copper Retirements are necessary to respond to various factors in the Outside Plant, including road construction, maintenance problems, and growth accommodation.  Replacement cables may be either copper or fiber.  Specific information will be provided with each disclosure.

Locations, Timing of Deployments & Interface Requirements:

The following gives additional details on the copper retirement(s):

STATE WIRE CENTER PLANNED COMPLETION OR RETIREMENT DATE DA (s) Job # FDI Address(es) Replacing
CO Brighton BITNCOMA 12-30-2006 120631 6226846 15680 E. 168th PLACE 267' OF ANMW-25 & ANMW-400 IN PLACE OF 163' OF ANMW-400 & 150' OF ANMW-25. LOT LINES WERE CHANGED & CABLES WERE CUT DURING BUILDING CONSTRUCTION AND MUST BE RELOCATED. ANMW-25 BEFORE: .15KF OF 24 GAUGE FOR A LOSS OF .25dB @ 28 KHz ANMW-25 AFTER: .267KF OF 24 GAUGE FOR A LOSS OF .45dB @ 28 KHz ANMW-400 BEFORE: .163KF OF 24 GAUGE FOR A LOSS OF .27dB @ 28 KHz ANMW-400 AFTER: .267KF OF 24 GAUGE FOR A LOSS OF .45dB @ 28 KHz
CO Denver - NE DNVRCONE 12-31-2006 237410 C62A689 15350 E 117 AV QWEST WILL MOVE PED 15501-23. DUE TO THIS MOVE WE WILL NEED TO PLACE NEW CABLE AND ABANDON THE CURRENT CABLE. BEFORE AFTER 506' ANMW-25 @ 28KHz= .830 554' ANMW-25 @ 28KHz= .910 CHANGE3 OF +.080 LOSS REQUIRES DISCLOSURE NOTIFICATION.
CO Englewood ENWDCOMA 02-13-2007 411031 C62A368 X 1500 Hampden Ave Buried Facilities (45X) 414' of ANMW-300 146' of ANMW-200 35' of BKMA-200 306' of AFTW-100 144' of ANMW-50 142' of ANMW-25 25' of BKTH-25 Underground Facilities (5X) 150' of ANMW-50 140' of BKMH-25 Aerial Facilities (52X) 349' of BKMH-300 1198' of BKMH-200 35' of BKTH-100 164' of BKTH-50 292' of BKMH-50 359' of BKTH-25 180' of BKMH-25 378' of XXAL-50 Total cable lengths to be removed is 4457' of both buried and aerial cable.
MN Beard MPLSMNBE 01-05-2007 410403 52MN346 SAI Qwest will remove 90 feet of BKMP, 50 pair cable and one 12 pair terminal in the Beard, MN wire center. Work begins 13.056KFt from the central office. There is no service being fed from this cable and terminal. The terminal is 3810 West 31st Street, cable 3811-31, pairs 1-12.
MN MPLS Downtown MPLSMNDT 11-20-2006 130804 62MT552 245 11 Ave S The cable and terminal to 911 S 2 St in the Mpls Downtown wire center are going to be wrecked out for Qwest was notified that the building is going to be demolished. Qwest will be retiring a 24 gauge 100 pair cable 130'. and terminal I 917 S 2 st. Which is a 100 pair terminal.
MN Rochester ROCHMNRO 12-01-2006 390202 C6MA314 F12-A Replacing 2,242' of 19 & 22ga with 2,500' of 24ga. Before After 1,301 of 19 ga & 941' of 22ga @ 28KHz = 1.81 2,500 of 24 gauge @ 28KHz = 3.9
MT Gardiner GRNRMTMA 12-15-2006 120141 624D587 N/A Qwest is relocating facilities in conflict with bridge construction. F1/F2 cable - 232' of 22 gauge will be replaced with 246' of 22 gauge. The loss will increase +.01db.
ND Grand Forks GDFRNDBC 12-30-2006 325502 62FC244 X 500-2 This job replaces a section of buried 22 gauge cable with buried 24 gauge cable in East Grand Forks to restore cable damaged by a contractor. Before:22gauge @ 3.148kf @ 28khz=3.42db loss After: 22gauge @ 2.331kf & 24gauge @ .825kf @ 28khz=3.86 A difference of .44 db loss due to gauge change.
NE Valley VLLYNENW 12-22-2006 315551 62bc276 X 26414 Blondo Ct ONLY QWEST CUSTOMERS ARE CURRENTLY WORKING IN THE AFFECTED CABLE. LOOP LOSS AT 28 KHz IS 8.850 BEFORE JOB AND 9.120 AFTER JOB. 344' GFMW 100 IS BEING REPLACED BY 364' ANMW 100.
NM Belen Main BELNNMMA 02-15-2007 110511 & 110611 625M128 1322 Frontage Rd & 1-25 Bypass Qwest is cutting from a copper fed DA to a fiber fed CSA. This will also realign the serving area's to provide better service. The dB loss will be lowered from 30.900 @ 28KHz to 19.38 @ 28KHz. The F-2 cables will stay at 24 gauge but will have kess length. The buried cable sections to be abandoned in place are F-2 facilities from 1322F that are being removed and cut over to the 51-BP counts
OR Eugene EUGNOR53 12-12-2006 2108 C6RA292 N/A The work begins at 8.0 Kft from the Eugene Central Office. Before After 130' of ANMW-100 @ 28 KHz = .22 172' of ANMW-100 @ 28 KHz = .29 A change of +0.07 dB loss. This job places 172' of 100 X 24 ga underground cable and abandons 130' of 100 X 24 ga underground cable.
UT Bountiful BNTFUTMA 12-18-2006 212011 H160027 795 W 1600 S UDOT project SP-0067(5) Legacy Parkway. UDOT is constructing the Legacy Parkway from Farmington to North Salt Lake. These facilities are in conflict with the parkway and need to be relocated. The dB loss calculations for the individual copper cable sections are: Before: 1960' of ANMW-50, 118' of BKMH-50, 996' of BKMA-25, 371' of ANMW-100, 289' of GFAW -50, 224' of AFTW-200, 24' of AFTW-100, 121' of BKMH-100, 598' of AJMW-100, 25' of GFMW-100 @ 28KHz=7.87. After: 1887' of ANMW-25, 1638' of ALAW-100, 35' of BHAH-300, 3601' of ALMW-200, 379' of AJMW-300, 25' of GFMW-25 @ 28KHz=10.77. Change of +2.9dB loss. Short interval disclosure is required.
UT Lehi LEHIUTMA 12-01-2006 211703 626T676 SAI Relocating aerial cable to the buried enviromant, this will add an additional 56' of of 24 gauge cable and an increase of 0.09 db loss @ 28khz.
UT Pleasant Grove PLGVUTMA 12-08-2006 125001 C66A224 X 9600 N Hwy 146 Removing 620' of Aerial 24ga. cable. This will be replcaed with 755' of buried 24ga.
Additional Information:

Any customer premises equipment vendor/manufacturer or enhanced services provider desiring additional technical information in conjunction with this Disclosure can contact:

Georganne Weidenbach
Regulatory Compliance Manager
Georganne.Weidenbach@qwest.com

This Network Disclosure is available as a PDF download (file size: 112Kb). If you need to print Network Disclosures, the PDF file will give you more flexibility and a higher quality printout than will a Web page, which is designed to be viewed with a Web browser. If you need the Adobe Reader, you can download it for free from Adobe's Web site.

Back to Top - Net Disclosure Main Page
Net Disclosures Listed Numerically

Questions regarding Network Disclosure information can be referred to the individual listed on the Disclosure Announcement or e-mail Dean Martineau, Qwest's Manager of Network Disclosures at a.martineau@qwest.com.