Copper Retirements in Arizona, Colorado, Idaho, Iowa, Minnesota, Montana, Nebraska, New Mexico, North Dakota, Oregon, South Dakota, Utah, Washington and Wyoming

First Implementation Date:

September 19, 2006

Original Date Posted:

September 27, 2006

Summary:

Copper Retirements are necessary to respond to various factors in the Outside Plant, including road construction, maintenance problems, and growth accommodation.  Replacement cables may be either copper or fiber.  Specific information will be provided with each disclosure.

Locations, Timing of Deployments & Interface Requirements:

The following gives additional details on the copper retirement(s):

STATE WIRE CENTER PLANNED COMPLETION OR RETIREMENT DATE DA (s) Job # FDI Address(es) Replacing
AZ Cottonwood CTWDAZMA 11-30-2006 210021 110132 621X777 X 1 HWY 279, X 2386 S Copper Dr This job will reroute existing cables for a road improvement project. The dB loss will be negatively impacted +0.5dB @ 28KHz on F1 counts EX1,1-200 & EX2,501-600. The existing ANMW-300pr cable is 949ft long (will be abandoned) and will be rerouted through 1245ft of new ANMW-400pr cable. There will also be a negative impact of +0.73dB on F2 count S101,301-400. The existing ANMW-100pr (will be abandoned) cable has a loop length of 500ft. The new loop length will use a portion of the new ANMW-400pr cable and ANMW-100pr. The new loop length will be 930ft using both 400pr & 100pr cables. All of the cables are along Hwy 260 near Western Ave.
AZ Glendale GLDLAZMADS0 11-20-2006 511872 6216734 N/A THIS JOB REPLACES 1300FT SECTION OF Bhah-600 with Anmw-600 pr cable . This cable section will go from mh 6498 North to south side of Myrtle av. Breaking out of existing conduit just south of Myrtle av. ending at buried splice. This replacment of 22 gauge cable with 24 gauge changed the Db loss of 1.51 to 2.26 db.
AZ Tempe TEMPAZMA 09-19-2006 310421 N/A None, direct feed THIS JOB WILL REPLACE A 200 PAIR AERIAL CABLE FOR APPROXIMATELY 1000 NORTH OF CURRY AND EAST OF VAN BUREN. THE EXISTING DB LOSS IS 1.7 AND AFTER REPLACEMENT WILL BE 1.88.
AZ Yuma Main YUMAAZMA 12-15-2006 134590 6212859 313621 THIS JOB WILL REPLACE EXISTING COPPER CABLES (220' OF 24 GUAGE WITH A DB LOSS OF 0.59DB). WILL BE REPLACED WITH 225' OF 24 GUAGE (0.61DB). The MINIMAL LOSS WILL NOT AFFECT THE LOOP
CO Boulder BLDRCOMA 09-29-2006 210532 C62A563 X 2549 26 This job cuts dead and abandons 45' of a 26 Gauge cable placed in 1978 from ped 2625 to a bldg at # 2625 28th St. This work is at the request of the developer due to interior demolition of this building. Expedited time frame is required as the demolition is scheduled to start on 9/21/2006.
CO Boulder BLDRCOMA 10-06-2006 110585 C62A558 X 121 7 Balsam This job removes 79' of aerial 26 ga cable from a building at #2834 Broadway to P 2833 in the alley west of Broadway and north of Balsam. This work is required by the developer as the building is being demolished. Expedited retirement is required for the demolition which is scheduled fo the 1st week of October.
CO Colorado Springs Main CLSPCOMA 03-01-2006 412081 6221835 X 2326 N Circle Dr this job will replace the existing 292' of 24GA and 30' of 24 GA ( with DB loss of 35.09) with 325' 24 GA ( 35.100 DB) This job will replace 352' of 24 GA (with DB loss .580) with 540' 24 GA (0.880 DB loss) This job will replace 30' of 24 GA( 0.050 DB loss) with 188' 24 GA (0.320 DB loss)
CO Denver Southwest DNVRCOSW 12-19-2006 210733 6225826 9850 W. Girton Dr THIS JOB WILL REPLACE EXISTING COPPER CABLE (395' OF 26 GUAGE WITH DB LOSS OF .980). IT WILL BE REPLACED WITH 415' OF 24 GUAGE (.680 DB). THE MINIMAL LOSS WILL NOT AFFECT THE LOOP.
CO Denver East DNVRCOEA 10-13-2006 410662 C62A467 X 1473 Xenia RETIRE 110' OF 24 GAUGE 25 PR AND 50 PR CABLE AND REPLACE W/ 135' OF 24 GAUGE 25 PAIR CABLE TO EXISTING BUILDING 1460 XENIA ST. BEFORE 110' OF 24 GAUGE 25 PAIR AND 50 PAIR CBL AT 28 KHZ =0.190 DB AFTER 135' OF 24 GAUGE 25 PAIR CBL AT 28 KHZ = 0.230 DB THIS SHOWS A NEGATIVE IMPACT OF +0.040 DB.
CO Denver East DNVRCOEA 11-03-2006 322011 C62A333 X 2958 Central Park Blvd RETIRE 253' OF 24 GAUGE 400 PR CABLE AND REPLACE W/ 268' OF 24 GAUGE 400 PAIR CABLE WITHIN STAPLETON FILING 9C (E 29TH PL AND ULSTER ST). BEFORE 253' OF 24 GAUGE 400 PAIR CBL AT 28 KHZ =0.420 DB AFTER 268' OF 24 GAUGE 400 PAIR CBL AT 28 KHZ = 0.450 DB THIS SHOWS A NEGATIVE IMPACT OF +0.030 DB.
CO Denver South DNVRCOSO 11-30-2006 220232 622N352 X 163 Humboldt QWEST is splicing cable that has been previously placed on a rehab job in 2000. The sections to be replaced are straight feed terminals that will be cut behind X 163 Humboldt. The 2499' of 22 gauge cable was replaced by 24 gauge cable. The dB loss of the section before is 2.67db. The db loss after is 3.89. This is a service affecting rehab and the RFS will be less then the 95 days.
CO Fraser FRSRCOMA 11-30-2006 110361 C62A292 272 Hi Country Dr Replace 850' of ALMW-300 pair feeder cable with 1270' of ANMW-400 F1 feeder. The existing 300 pair cable is being replaced due to a road realignment. The new F1 loop will be 6.03 KF from the CO.
CO Granby GRNBCOMA 12-30-2006 N/A 622C066 X 563 W. Agate Av Qwest is replacing a portion of F1 cable to x-box X-563 wW Agate Av. 1586' of aerial 24 gauge cable will be replaced with 2030' of buried 24 gauge cable. This will add 0.44 KF of 24 gauge to the loop length to the x-box.
CO Grand Junction GDJTCOMA 11-15-2006 431631 5223126 Direct Feed and X-2448 This job removes existing aerial and buried cables along River Rd for jobs 5222527, 5222684, 5222686 and 5222687. These jobs are required to relocate telephone facilities in conflict with the 2nd phase of the Riverside Parkway road project being done by the City of Grand Junction. These four jobs placed a total of 10,355' of 24 gauge F1 cable, 2007' of 22 gauge F2 cable and 6190' of 24 gauge F2 cable. Job 5222684 also replaced the X-box. These jobs replaced 10,273' of 24 gauge F1 cable and 3' of 26 gauge F1 cable. The (2) jobs that placed the F1 cable ( 5222527 & 5222684) resulted in an increase of 82' of new F1 cable. Job 5222687 is a direct C.O feed area and placed 2235' of 24 gauge cable. This replaced 2918' of 22 gauge, 212' of 24 gauge and 425' of 26 gauge. Altough there was a reduction in gauge, the removal of bridge-tap and multiples improved service in this area. jobs 5222684 & 5222686 placed a total of 2007' of 22 gauge F2 cable and 3883' of 24 gauge F2 cable. These cables replaced 9506' of 22 gauge F2 cable and 621' of 24 gauge F2 cable. Again, altough there was a reduction in gauge , service was improved with the removal of bridge-tap and multiples in this section. All service provided by these jobs will remain copper fed.
CO Parker Main PRKRCOMA 11-10-2006 219531 N/A X 3004 Pikes Peak Rd This job provides for replacing 2700 ft of ALBW-50 placed in 1977 that due to erosion over time has deteriorated to the point it is no longer usable. It will be replaced with 2712' ANMW-50 Before: 2700' ALBW-50 @ 28KHz =0.73Db After: 2712' ANMW-50 @ 28KHz = 1.26Db The existing 50 pr cable will be changed for 19 ga to 24ga due to the fact that this area is well within RZ1500 and will continue to support services without needing the course gauge.
CO Snowmass SNMSCOMA 12-08-2006 111391 C62A541 2801 Upper River Rd This job is located 19.6kf from the Snowmass Central Office and 2.62kf from X-Box 2801 Upper River Rd. Copper retirements are as follows: BEFORE 410' of BHAA-50 @ 28KHz = 0.512/410' of BHBA-50 @ 28KHz = 0.305 AFTER 440' of ANAW-100 @ 28KHZ = 0.550. Change of 0.245dB loss.
IA Cedar Falls CDFLIACO 01-15-2007 210104 62CE314 X 1810 Clay (1) BKMP-200 cable placed in 1997 is being abandoned in place due to road project and replaced with like gauged cable but is 214 feet longer. Before copper retirement, 950'BKMP-200@1004Hz=2.150dB loss. After,1,164'ANMW-200@1004Hz=2.200dB loss. Change of -0.050dB loss.
IA Clarion CLRIIACO 10-27-2006 221101 62CE685 X City Limits This job replaces two sections of cable 11pr-19ga and 25pr 24ga with new 24ga 50pr cable. One section is 300' the other section is 600'. The loop will be affected on the 19ga cable that is replaced with 24ga cable. The entire length of the loop from the co to the end terminal is 11.787kf
ID Twin Falls TWFLIDMA 10-20-2006 112001 C63A226 X 175 Ash BEGINNING AT .722Kf BEYOND X 175 ASH, 402' OF AERIAL ANMW-100 IS BEING REPLACED AND REROUTED WITH 542' OF ANMW-100 TO CLEAR AREA FOR CONSTRUCTION OF BUILDING ADDITION TO FIRST ASSEMBLY OF GOD CHURCH. SERVICE AFFECTING RETIREMENT EXCEPTION IS REQUIRED DUE TO CONSTRUCTION SCHEDULE OF BUILDING ADDITION. BEFORE 402' OF ANMW-100 @ 28KHz=.660 AFTER 542' OF ANMW-100 @ 28KHz=.890 CHANGE OF +.230dbLOSS.
MN Faribault FRBLMNFA 01-15-2007 140403 62MR684 X TH3 & CSAH 29 THIS JOB WILL REPLACE EXISTING CABLE (270 FEET OF 22 GUAGE WITH A Db LOSS OF 0.670). THE 270 FEET WILL BE REPLACED WITH 390 FEET OF 24 GUAGE (1.080Db)
MN Fernbrook PLMOMNFE 12-30-2006 110303 110705 42MK703 X 6448 Berkshire Ln This Job is replacing an existing RT 6450 BERKSHIRE LN and SAI X 6448 BERKSHIRE LN. The existing SAI has a mixed copper-pair gain feed. The new SAI will be all pair gain on fiber.
MN Forest Lake FRLKMNFL 09-20-2006 110502 62MR199 X 408 4 AV NW Qwest has retired and made unusable 233 feet of 24ga cable which has a dB loss of .390 @ 28 KHz. The remaining F1/F2 loop is 7.214 Kft.
MN Forest lake FRLKMNFL 09-20-2006 410103 62MR199 X 1198 11 AV SW Qwest has retired and made unusable 10 feet of 26ga cable which has a dB loss of .030@ 28KHz. The remaining loop is 5.367 Kft.
MN Forest Lake FRLKMNFL 09-20-2006 310202 62MR199 X Forest Rd-202 St Qwest has retired and made unusable 1560 feet of 24ga cable which has a dB loss of 2.450@ 28KHz. The remaining loop is 6.585 Kft.
MN Melrose DLTHMNME 11-15-2006 N/A 62MR468 X 301 South Lake QWEST WILL ABANDON 600' OR AFMW-25 CABEL AND REPLACE IT WITH 800' OF ANMW-25, and 174' of AFTW-25.
MN MPLS Donwtown MPLSMNDT 10-31-2006 511702 C6MA242 3811 W 31 St Work consists of replacing replacing 130' of 26 gauge cable with 240' of 24 gauge cable inside in the basement of 110 N 5th St. The change in dB is +.06dB loss.
MN Red Wing RDWNMNRW 10-30-2006 420302 62MR307 X C11A Abandon 1020'of AJAW-11,170'of ANAW-25 @28KHz=1.260db replace with 1190' of ANMW-25 @28KHz=1.890db a change of +.63db which will negatively affect the loop makeup.
MT Clancy CLNCMTMA 12-29-2006 310541 C64a051 X 72 Warm Springs Creek Rd THIS JOB PROVIDES FOR RELOCATING CLOSURE 63/12.8 APPROXIMATELY 80' NORTH WHICH INCLUDES PLACING APPROXIMATELY 94' OF ANMW-50, 94' OF ANAW-100, ALL IN ROUTE 3/4 OF THE CLANCY WIRE CENTER. THIS WORK BEGINS 12.8KF FROM THE CLANCY CENTRAL OFFICE. THE db LOSS CALCULATION FOR THE COPPER CABLE SECTION IS AS FOLLOWS: BEFORE: AFTER: 80' ANAW-100 @ 28KHz = 0.090db 92' ANAW-100 @ 28KHz = 0.100 CHANGE OF +0.010db LOSS REQUIRES NOTIFICATION DISCLOSURE. 80' ALMW-50 @ 28KHz = 0.140db 92' ANMW-50 @ 28KHz = 0.160 CHANGE OF =0.020db LOSS REQURIES NOTIFICATION DISCLOSURE.
ND West Fargo WFRGNDBC 12-08-2006 311211 62FC140 CCT1740AV This work will consist of replacing 381 feet of ANAW 100 pair @ 28 KHz = .410 dB with 381 feet of ANMW-50 pair @ 28 KHz=.630 dB. Change of +.22dB loss. This project is relocating the existing facilities for a water project the City of West Fargo is doing in Windsor Green Estates.
NE Fremont FRMTNENW 11-03-2006 115151 62BC085 N/A EXISTING 2420' OF ALAW-25PR HAS BEEN DAMAGED AND EXPOSED IN MINIMUM MTCE RD, TO BE REPLACED WITH 2550' OF ANAW-25PR. CABLE NEEDS TO BE REPLACED ASAP SINCE IT HAS BEEN TEMP REPAIRED AND IS IN JEOPARDY TO BE DAMAGED AGAIN. THIS IS ON 862 RD BETWEEN 590 & 591 AVE. THIS IS F1 COUNT IN THE RURAL AREA.
NM Las Cruces Main LSCRNMMA 10-15-2006 130201 625K795 X 4000 W Picacho Ave Qwest is replacing buried 19 gauge cable 420' at Shalem Colony starting at Crow rd going south with buried 24 gauge cable 420'. Cable going north is affected with an addition of .55 db loss on DSL. The new f2 loop from x-box to farthest terminal will be 10.948 KF and will still support DSL and or LNSHR. Currently there is no CLECs on this cable. Short interval is requested with 19 gauge cable wet and failing, currently there is drops to keep service intact.
OR Hermiston HMTNOR56 01-12-2007 320911 62RT141 X 2651 Feedville Rd Replacing 3360ft of 6PR 22GA BSW with 1820ft of 25PR 24GA and 1540ft of 50PR 24GA buried cable.
OR Seaside SESDOR64 09-29-2006 2306 62RT285 X 83189 Highway 53 Qwest is replacing 2 existing cables that were damaged by a log truck. Existing cables AFAW-50 & BHAA-25 are being replaced with an ANMW-100. This is the cable that is on hand and this is a damaged cable with numerous service outages.
OR Springfield SPFDOR01 11-01-2006 414704 C6RA225 X 391 Lindale Dr THIS JOB RETIRES EXISTING AERIAL CABLE ON LAURA STREET IN FRONT OF THE BANBERRY ASSISTED LIVING CENTER. THE NEW BURIED CABLE WILL BE SLIGHTLY LONGER. THE DB LOSS FOR THIS CROSS CENNECT (391 LINDALE ST) WILL BE .3 DB GREATER AFTER WORK IS COMPLETE. THIS WORK HAS TO BE COMPLETE BY MID OCTOBER BECAUSE OF CITY OF SPRINGFIELD ROAD PAVING SCHEDULES. Before: After: 275' of BKMH @ 28KHZ=.46DB 460' of ANMW @28KHZ=.76DB
SD Canton CNTNSDCO 05-25-2007 410102 C6TA052 Central Office LINCOLN COUNTY, SD IS BUILDING AN ADDITION ON TO THE COURTHOUSE IN CANTON, SD, QWEST FACILITIES WILL BE LOWERED FOR THIS PROJECT. THIS CABLE TA-335-S IS NOT BURIED WITH THE REST , THE SECTION UNDER THE NEW ADDITION WILL BE ABANDON AND RE-SPLICED INTO AT THE NEW MANHOLE THAT IS TO BE PLACED ON THIS JOB. THE COUNT WILL BE TRANSFERRED TO THE AFTW-9 CABLE TO GO UNDER THE COURTHOUSE ADDITION AND WILL BE TRANSFERRED BACK TO THE REMAINING TA-335-S CABLE IN THE NEW MANHOLE.
UT Heber City HBCYUTMA 10-31-2006 411891 626R917 X 1163 Swiss Alpine Rd RELOCATE EXISTING BURIED CABLE IN THE WAY OF THE MATTERHORN VILLAGE PHASE 2 SUBDIVISION. CHANGE IN TRANSMISSION PROPERTIES. BEFORE: 270' OF ANMW-25 (24 GAUGE) CABLE- 28KHz= 7.080KF AFTER: 887' OF ANMW-25 (24 GAUGE) CABLE- 28KHz= 9.380KF RETIREMENT CANNOT WAIT THE 95 DAYS DUE TO CUSTOMER CONSTRUCTION, EXISTING CABLE IN THE WAY OF NEW DEVELOPMENT.
UT Logan LOGNUTMA 10-13-06 218431 626P705 1318 N 400 WEST Logan City road project 05-024. Logan City will be widening 400 West between 1400 an 1600 North. Qwest has 2 pedistals in conflict with these plans that will be relocated. The dB loss calculations for the individual copper cable sections are: Before: 6' of ANMW-600 @ 28KHz=.01 After: 60' of ANMW-600, AFMW-600 @ 28KHz=0.10 Change of +.09dB loss requires notification disclosure. Short interval disclosure is required. Before: 6' of ANMW-900 @ 28KHz=.01 After: 60' of ANMW-900, AFMW-600 @ 28KHz=0.10 Change of +.09dB loss. Short interval disclosure is required.
WA Kent Obrien KENTWAOB 12-31-2006 231601 62W1516 410 SW 34th QWEST WILL SECTION THROW PAIRS 410-34,176-183 & 410-34,476-483 IN MANHOLE 373 IN THE KENTWA0B WIRE CENTER TO MANHOLE 368 IN THE RNTNWA01 WIRE CENTER TO A NEW CABLE. THIS WILL ALLOW FOR REMOVAL OF OLD IOF COPPER CABLE. NO CLEC SERVICES ON CABLE. BEFORE = 7.202KF AFTER = 4.452
WA Kent Ulrich KENTWA01 10-10-2006 230302 N/A X 10820 SE 200th Job C6WA353 places 1.2kf ANMW-25 aerial cable attaching to PSE poles on the north side of SE 200th St from SE 108th to SE 112th. Job removes .845kf of 22GA, .065kf 24GA cable on the south side of SE 204th St. Copper Retirement db loss calculations result in a -.05db loss difference. Befor 1.313kf @ 1004 Hz =0.480 After 1.175kf @ 1004 Hz =0.530 Work is in route 2 of Kent Ulrick Wirecenter at 23.5kf from the CO. F_1 cable is Loaded
WA Tacoma Juniper TACMWAJU 11-17-2006 231101 C6WA105 1108 McChord Qwest is cutting away all copper and RT at Bldg 1108 McChord AFB. This will be replaced with a new count from a Remote Terminal at Bldg 100 McChord AFB. The existing numbers and/or circuits will need to be cut to the RT. This RT does support DSL. The new F1 loop will be 0.200 Kft.
WY Jackson JCSNWYMA 12-31-2006 416101 C67A049 X 1275 N Third REPLACE 204' OF BHBS-25 AERIAL CABLE WITH 269' OF ANMW-25 BURIED CABLE ON N WEST ST IN WILSON WEST OF JACKSON
Additional Information:

Any customer premises equipment vendor/manufacturer or enhanced services provider desiring additional technical information in conjunction with this Disclosure can contact:

Georganne Weidenbach
Georganne.Weidenbach@qwest.com

This Network Disclosure is available as a PDF download (file size: 112Kb). If you need to print Network Disclosures, the PDF file will give you more flexibility and a higher quality printout than will a Web page, which is designed to be viewed with a Web browser. If you need the Adobe Reader, you can download it for free from Adobe's Web site.

Back to Top - Net Disclosure Main Page
Net Disclosures Listed Numerically

Questions regarding Network Disclosure information can be referred to the individual listed on the Disclosure Announcement or e-mail Dean Martineau, Qwest's Manager of Network Disclosures at a.martineau@qwest.com.