Public Notice of Network Change(s), Pursuant to CFR 47, subsections 51.325 - 51.335. Qwest's Internet address: http://www.qwest.com/disclosures.

Copper Retirements in Arizona, Idaho, Iowa, Minnesota, Montana, New Mexico, North Dakota, Oregon, Utah, Washington and Wyoming

First Implementation Date:

September 11, 2006

Original Date Posted:

September 8, 2006

Summary:

Copper Retirements are necessary to respond to various factors in the Outside Plant, including road construction, maintenance problems, and growth accommodation.  Replacement cables may be either copper or fiber.  Specific information will be provided with each disclosure.

Locations, Timing of Deployments & Interface Requirements:

The following gives additional details on the copper retirement(s):

STATE WIRE CENTER PLANNED COMPLETION OR RETIREMENT DATE DA (s) Job # FDI Address(es) Replacing
AZ Higley Main HGLYAZMA 09/11/06 310421 18401 E. San Tan Blvd THIS JOB WILL REPLACE A 950' OF 100 PAIR AND 350' OF 50 PAIR 22 GAUGE CABLE THAT WAS DAMAGED AND WILL BE REPLACED WITH A 24 GAUGE CABLE ON GRAPEFRUIT DRIVE FROM MEWS ROAD SOUTH TO SAN TAN BLVD. EXISTING CABLE DB LOSS IS 1.74 AND NEW CABLE DB LOSS IS 2.63.
UT Clearfield CLFDUTMA 09/15/06 218661 626D549 Direct Feed from CO Clinton City Project - 2300 North-1500 West to 2000 W & 2050 North-1720 W to 1500 W - Roadway reconstruction. The City is adding curb, gutter and sidewalk along 2300 N & 2050 N. Qwest will be relocating 9 pedestals and adding approximately 176' of ANAW 50 pair cable.
The dB loss calculations for the individual copper cable sections is:

Before - 2278' - 22 gauge 50 pair @ 28 KHz = .230
After - 2454' - ANAW 50 pair @ 28KHz=.430
Change of +.2 dB loss does require notification disclosure. Short interval disclosure is required.
NM Clovis CLVSNMMA 09/18/06 411901 625H869 X 430 TEP This work begins 10.919 kft from tne CLVSNMMA CO. The db calculations are as follows:
BEFORE: 614' of BHAA-100 @ 28khz = .720 db. AFTER: 671' of ANMW-a00 @ 28 khz = 1.200 db.
A change of +.48 db requires disclosure. A short interval disclosure is required due to out of service conditions. The ERFS for this job is 09/18/06.
MT Bozeman BZMNMTMA 9/25/06 452511 C64A045 X 4 Simmental Way This billing job will reroute aerial cable facilitiy into buried cable placed in customer provided conduit. 1.270 KFT of 19 GA cable will be replaced by 1.393 KFT of 24 GA cable. The old total loop loss at furthmost terminal I 6130 DAVIS LN was 11.9 db at 1004 KHZ while the new loss is db. at 40 KHZ old loss was 26.5 db while the new loss is 28.9 DB. HICAP ckts still qualify for non-repeatered HDSL.
IA Cedar Rapids North CDRRIANO 09/29/06 211505 C6CA126 X 279 Collins Rd Abandon 172' of AFMW-200 placed in 1982, 110' of ANMW-100 placed in 1995, 219' of GFMW-100 placed in 1994 and 142' of ANMW-50 placed in 2006 due to improvement project at 4701 1st Ave SE
MN Crystal CRYSMNCR 09/29/06 430302 62MR356 X 6408 West Broadway Building Demolition - Building was demolished without notice and new park & ride facility is under construction. Short Term Notice is required.
AZ Tucson Main TCSNAZMA 09/29/06 110131 6216160 Direct Feed THIS WORK WILL REMOVE 117' OF DSML-100 PAIR UNDERGROUND CABLE AND TEA @ I 38 AND 48 E CONGRESS THIS CABLE AND TERMINALS WILL BE DISCONNECTED FROM THE EXISTING CABLE NETWORK AND REMOVED FROM THE FIELD.REMOVAL OF THIS CABLE WILL HAVE NO NEGITIVE IMPACT OR DB LOSS TO EXISTING NETWORK.
NM Albuquerque Southwest ALBQNMSW 09/30/06 311101 625H643 X 1 Pajarito RD S W This job placed 2750' of anmw-50 and removed 352' of BHAA-50 placed in 1969, and 2398' of XXBL-26 placed in 1948. This work is necessary due to rain and lightning damage. There are no affected CLEC services. The dB loss changes from 50.91 to 54.82.
OR Winston WNTNOR57 9/30/06 112261 62RT035 Qwest will abandon 1000 feet of BHBA-25 cable and replace it with 1000 feet of ANAW-50 cable on the west side of Roberts Mountain Rd. south of Roberts Creek Rd. This work will change the loop makeup of this transmission path.
MN Franklin MPLSMNFR 10/01/06 420303 62 X 1419 Nicollet Ave Building Demolition - Removal of facilities. I 1375 Willow St.
MN Princeton PRTNMNPR 10/2/06 410102 62MR242 SAI 2.705 Kft of 19 gauge cable will be replaced with 3.094 Kft of 22 gauge cable because of a road job in this area.
MN Melrose DLTHMNME 10/06/06 110610 62MR037 Office Direct Pairs Removing a 100 pair inside building terminal and 20 ft of BKMH-100.
MN Melrose DLTHMNME 10/06/06 411002 C6MA228 314 S Blackman Ave Qwest will be abandoning 190' of BKMH-25 and removing 17' of BKMH-25 and a 25 pair building terminal. Customer has constructed a new building; services will be moved over to new building.
MN Owatonna OWTNMNOW 10/13/06 411502 X Brady Blvd Qwest will abandon 80' of ANAW-200 pair, 22' of ANMW 100 pair, 893' of AHAA-100 pair and 1442' of BHAH-100 pair buried distribution cables and replace with 555' of ANMW-200 pair, 485' of ANMW-100 pair and 930' of ANMW-50 pair buried distribution cables. Escalation is required because of road reconstruction. The change in the loop makeup is minimal: Before 12.7 KF with 21 dB loss @ 28 KHz / After 12.9 KF with 22 dB loss @ 28 KHz.
MT East Glacier EGPKMTMA 10/15/06 220241 H540021 NA Qwest is relocating facilities in conflict with state highway project. F1/F2 cable - 860' of 24 gauge will be replaced with 900' of 24 gauge. The loss will increase +.060db. Toll facility - 860' of 22 gauge will be replaced with 900' of 22 gauge. The loss will increase by +0.04db.
OR Phoenix PHNXOR55 10/15/06 1108 62RN549 3840 Fern Valley Rd This job is affecting terminal 3001 N Phoenix Road. No CLEC Customers. The dB loss originally was 5.7dB and now it will be 6.28 dB. The length of the cable is the only thing that is changing, the gauge is the same. This work had to be done due to a realignment of N Phoenix Road due to new business development.
MN St. Paul Midway STPLMNMI 10/30/06 210705 C6MA224 X 1247 ST ANTHONY This job will replace existing copper F1 cables (1,146' of 24G, 200' of 26Ga and 1-20' 24GA Stub) having a dB loss of 18.750@28KHz with F2 copper cables (655' of 24G and 1-30' 24Ga Stub) and UG rearrangements having a dB loss of 19.930@28KHz. The change of -1.18dB will affect the loop but provides F2 facilities to terminal I 470 Hamline Av N.
IA Correctionville SHLNIATC 10/31/06 410504 62CE439 X 3 Av & 16 St Replacing .372 kf of BHAH-150 with .385 kf of ANAW-200.
BHAH-150 OLD F2 route of .372KF @ 28KHz=.400 db
ANAW-200 NEW F2 route of .385KF @ 28KHz=.410 db. Change of .01 dB loss.
MN Winona WINOMNWI 10/31/06 210602 C6MA235 X 71 E 2 ST This cable is being abandoned and no cable placed due to the demolition of eight buildings for a new parking lot.
MN Melrose DLTHMNME 11/07/06 320602 C6MA238 Office Direct Cable = 1 REMOVEING 2 CABLES 90' OF ABMM-200 HOUSE CABLE PLACED IN 1981.CABLE ALREADY ABANDONED REMOVEING THE CABLE NOW.
MN Little Falls LTFLMNLF 11/10/06 210204 X 1600 1st Ave NE RPL 2149' 24g & 26g CABLE W/ 2249' 24g CABLE FOR +.18dB loss. RPL 640' 24g CABLE W/ 700' 24g CABLEFOR +0.1Db LOSS. ABANDON 486' 26g 100 PR CABLE WITHOUT REPL.
WA Lacey LACYWA01 11/15/06 238002 52WA670 X 8370 Pacific Hwy Convert from buried to underground in sections along Pacific Hwy. Change 2030' of 22Ga - 2.15DB to 2030' of 24Ga - 3.16DB and 491' of 19 ga - .28DB to 491' of 24 ga - .81 DB.
WY Casper CSPRWYMA 11/17/06 4232 627C285 32.4 RL 10 Replace 516' of 19GA filled cable with 540' of 24GA filled cable. The existing 19GA has numerous wet splices and is not economically repairable. Because this job will eliminate bridged taps, the transmission loss will actually be improved at all frequencies except 1004 hz. At that one frequency, the loss will increase by 0.06db.
ND West Fargo 12/03/06 340102 62FB126 X CCT 100-3 This project will consist of abandoning 152' of BHAH-200, 486' of ANAW-50, 116' of ANAW-25 and replacing it with 47' of ANMW-200, 785' of ANMW-50. This work order will be adding +.37dB loss @28 KHz
NM Tijeras TJRSNMMA 12/11/06 218301 625H283 242 Sedillo Rd Removing existing cable and replace w/ like for like cable size of ANMW-50. Change of footage will impact loop make-up from new cable footage of 3,984' from 2,470 is 2.14dB loss. Job needs to be done for which is a PNM Electric NJUNS - Joint Use attachments to new PNM pole. Qwest has to get off of old poles within 30 days. Distribution Area is 31.6 Kft from Tijeras Central Office. The required service date is November 28,2006.
WA Orchard ORCHWA01 12/13/06 229632 C6WA366 15820 NE 28th Remove 1-25' ANMW 600 pr stub and the associated 20+' of ANMW 600pr to the utility hole wall. Abandon from the utility hole wall out the remaining 85' of ANMW 600. Abandon 132' of buried ANMW 400. There are no working services in these cables. There is no foreseeable impact associated with this removal.
ID Caldwell CLWLIDMA 12/31/2006 310802 623D972 X 3790 S 10 AV Distance (in KF) from the serving Wire Center or Remote Terminal: 12.2 KF. Description: This project abandons 403 ิof BKMH-100 cable and replaces it with 465' of ANMW-100. at the intersection of N 10 AV and Ustick Rd in route three of the Caldwell Idaho Wire Center.
Before: 403' BKMH-100 @ 28KHz = 0.670
After: 465' ANMW-100 @ 28KHz = 0.740
Change requires notification disclosure This has a negative effect on the loop conditions. X 3790 S 10 AV is 11.2 kf from the CO. Longest loop affected is 13.45 Kf
AZ Deer Valley 12/31/06 112831 6212692 X 3024 W Foothills DR This engineering work order will replace and relocate buried facilities in route 1 of the Deer Valley wire center to eliminate conflicts with improvements to be constructed on City of Phoenix project ST85100146/147. The work will consist of replacing various lengths, from .038 Kft. to 1.076 Kft., and gauges, 22-26, of buried cable with various lengths, from .043 Kft to 1.27 Kft. of 24 gauge buried cable. The work will affect the distribution counts 603,1-500, 603,526-600.
WA Yakima 2/13/07 4120 62WV592 X 2801 River Rd Miscellaneous F2 originating at X 2801 River Rd to field. Cable count is 2801RR, 151-175. The work is being done to accommodate a road improvement project. The work replaces 63 feet of 26 gauge cable with 204 feet of 24 gauge cable for a dB loss at 28 KHz of +0.190 dB over the existing cable. The SAI is fed from copper F1.
MN Elk River EKRVMNER 04/13/07 150502 & 150503 62MN421 X CR 33 & Concord & X CR 33 & Watson Road construction will begin in the 3rd quarter of 2006 for the reconstruction of County Road 33 and County Road 77 (Route 2), between Hwy 169 and County Road 1 in the city of Elk River. All existing F1 buried cables in DA 150502 & 150503 (22 ga.) will be abandoned and replaced with new 22 ga. in the area covered by this road job. All working services in the F1 cable(22 ga) will be cut to the new F1 (22 ga.) cables. All existing F2 buried cables in DA 150502 & 150503 (24 ga.) will be abandoned and replaced with new 24 ga. in the area covered by this road job. All working services in the F2 cable(24 ga) will be cut to the new F2 (24 ga.) cables.The existing cable lengths and new cable lengths for the F1 will change a little but will not have any significant affect. The existing cable lengths for F2 will change a little due too removing the two SAI's and moving the location of the one new SAI that is replacing the two, but will not have any significant affect. All existing cables (22 ga. & 24 ga.) will be replaced with the same gauge cables.
Additional Information:

Any customer premises equipment vendor/manufacturer or enhanced services provider desiring additional technical information in conjunction with this Disclosure can contact:

Georganne Weidenbach
Georganne.Weidenbach@qwest.com

This Network Disclosure is available as a PDF download (file size: 112Kb). If you need to print Network Disclosures, the PDF file will give you more flexibility and a higher quality printout than will a Web page, which is designed to be viewed with a Web browser. If you need the Adobe Reader, you can download it for free from Adobe's Web site.

Back to Top - Net Disclosure Main Page
Net Disclosures Listed Numerically

Questions regarding Network Disclosure information can be referred to the individual listed on the Disclosure Announcement or e-mail Dean Martineau, Qwest's Manager of Network Disclosures at a.martineau@qwest.com.