Qwest
Customer Service Search
Home - Residential - Small Business - Large Business - Partners - Wholesale
Network Disclosures


Network Disclosure Announcement #554

Public Notice of Network Change(s), Pursuant to CFR 47, subsections 51.325 - 51.335. Qwest's Internet address: http://www.qwest.com/disclosures.

Copper Retirements in Arizona, Colorado, Idaho, Iowa, Minnesota, Montana, New Mexico, Oregon, Utah & Washington

First Implementation Date:

April 28, 2006

Original Date Posted:

April 26, 2006

Summary:

Copper Retirements are necessary to respond to various factors in the Outside Plant, including road construction, maintenance problems, and growth accommodation. Replacement cables may be either copper or fiber. Specific information will be provided with each disclosure.

Locations, Timing of Deployments & Interface Requirements:

The following gives additional details on the copper retirement(s):

1 STATE ARIZONA
WIRE CENTER SHEA
8-CHARACTER SWITCH ID SCDLAZSH
COMPLETION DATE/PLANNED RETIREMENT DATE 07-30-2006
DA (s) 110522
FDI Address(es) SAI 11150 N. 92ND ST
Replacing REMOVING 1847' OF EXCESS CAPACITANCE BY CUTTING CABLE PAIRS DEAD AT MH 12256. 1.747KFT OF 24GA AND .100KFT OF 26GA. WILL BE REMOVED FROM THE LOOP. LOOP RESISTANCE ON SPARE CIRCUITS WILL IMPROVE BY 3.620DB @ 28KHZ. CIRCUITS ARE BEING TRANSFERRED OUT OF EXISTING CABLE TO EXISTING SPARE FACILITIES IN SAI. 1847' OF COPPER CONDUCTORS NO LONGER REQUIRED. CAN BE REASSIGNED AS SPARE COPPER CLOSER TO CENTRAL OFFICE.
NO CIRCUITS ARE AFFECTED AS PER LFACS
2 STATE COLORADO
WIRE CENTER WOODLAND PARK
8-CHARACTER SWITCH ID WDPKCOMA
COMPLETION DATE/PLANNED RETIREMENT DATE 07-24-2006
DA (s) 6183HWT 67
FDI Address(es) N/A
Replacing AERIAL PLANT PLACED IN THE 50'S DUE TO A POLE ALLINEMENT & UPGRADE.
THIS PROJECTS NEED TO COMPLETE BY JULY 24 2006
LOSS-DB BEFORE 1.230@28HKZ LOSS AFTER 1.850@ 28HKZ
RETIREMENT OF
1.184 OF BHAS-50 WILL BE REPLACE WITH BKMP-50
3 STATE COLORADO
WIRE CENTER BRIGHTON
8-CHARACTER SWITCH ID BITNCOMA
COMPLETION DATE/PLANNED RETIREMENT DATE 06-16-2006
DA (s) 214413
FDI Address(es) X 11199 TOWER RD
Replacing QWEST IS REPLACING A DEFECTIVE SECTION OF F1 CABLE CONTAINING DS1'S AND PAIRGAIN. THE EXISTING 22 GAUGE CABLE IS BEING REPLACED BY A 24 GAUGE SECTION AS THE PAIRGAIN AND DS1'S ARE DERIVED FROM A FIBER-FED REMOTE TERMINAL. THE SECTION BEING REPLACED IS 5.2 KFT FROM THE REMOTE TERMINAL. THE TOTAL DISTANCE FROM THE REMOTE TERMINAL TO X 11199 TOWER RD IS 7.3 KFT. THE REMOTE TERMINAL DOES NOT SUPPORT DSL SERVICE. THE NEW F1 LOOP WILL BE 7.35 KFT CONSISTING OF 6.55 KFT OF 22 GAUGE AND 0.8 KFT OF 24 GAUGE CABLE.
4 STATE IDAHO
WIRE CENTER CALDWELL
8-CHARACTER SWITCH ID CLWLIDMA
COMPLETION DATE/PLANNED RETIREMENT DATE 08-31-2006
DA (s) 210402
FDI Address(es) SAI X 424 S 16 AV
Replacing THIS WORK ORDER WILL PROVIDE FOR THE REPLACEMENT OF 379' OF BURIED 22 GAUGE CABLE PLACED IN 1956 THAT IS GOING WET. THE CABLE WILL BE REPLACED WITH 393' OF 24 GAUGE CABLE. THIS WILL RESULT IN A DB LOSS CHANGE OF +0.08 DB.
5 STATE IOWA
WIRE CENTER DES MOINES EAST
8-CHARACTER SWITCH ID DESMIAEA
COMPLETION DATE/PLANNED RETIREMENT DATE 05-31-2006
DA (s) 661104
FDI Address(es) X 1447 MILTON
Replacing THIS JOB WILL REPLACE 524' OF 22 GAUGE AERIAL LEAD CABLE WITH 520 FEET OF NEW 24 GAUGE SELF SUPPORT.THIS IS THE END OF CABLE RUN. NO CABLE IS EXTENDED BEYOND THIS POINT.
6 STATE MINNESOTA
WIRE CENTER LEXINGTON
8-CHARACTER SWITCH ID EAGNMNLB
COMPLETION DATE/PLANNED RETIREMENT DATE 07-31-2006
DA (s) 410308
FDI Address(es) X 3207 SIBLEY MEMORIAL HWY
Replacing ROAD RECONSTRUCTION WIDENDS ROAD 12' TO THE SOUTH. QWEST IS CUTTING THE WORKING LINES ON FEEDER CABLE TO THE SAI X 3207 SIBLEY MEMORIAL HWY. THE CIRCUITS WILL BE AFFECTED BY ADDITIONAL CABLE LENGTH. WORK BEGINS AT THE SAI 14 KF FROM THE CENTRAL OFFICE. THE DB LOSS CALCULATIONS ARE AS FOLLOWS: BEFORE/AFTER

IN 3045 HWY 13
(T1T-T1R) 7.7KF @ 11.7DB LOSS @ 28KHZ/(HDL2) 6.9KF @ 12DB LOSS @ 28KHZ
+0.3DB LOSS.
(POTS) 13.5KF @ 22.9DB LOSS @ 28KHZ/17KF @ 29.8DB LOSS @ 28KHZ
+6.9DB LOSS.
I 1710 ALEXANDER RD.
15KF @ 25DB LOSS @ 28KHZ/15.173KF @ 26DB LOSS @28KHZ
+0.173DB LOSS.
IN 3107 SIBLEY MEMORIAL HWY
(T1T-T1R)7.8KF @ 12.7DB LOSS @ 28KHZ/(HDL2)5.2KF @ 9DB LOSS @ 28KHZ
-3.7DB LOSS.
(POTS)14KF @ 24DB LOSS @ 28KHZ/15KF @ 27DB LOSS @ 28KHZ
+3DB LOSS.
IN 3103 SIBLEY MEMORIAL HWY
(T1T-T1R)13.5KF @ 23.7DB LOSS @ 28KHZ/(HDL2)6.3KF @ 10.6DB LOSS @ 28KHZ
-13.1DB LOSS.
(POTS)13.5KF @ 23.7DB LOSS @ 28KHZ/15.8KF @ 27.8DB LOSS @ 28KHZ
+4.1DB LOSS
F 3105 SIBLEY MEMORIAL HWY
(T1T-T1R)14.6KF @ 22DB LOSS @ 28KHZ/(HDL2)6.3KF @ 10.5DB LOSS @ 29KHZ
-11.5DB LOSS
(POTS)14.6KF @ 22DB LOSS @ 28KHZ/16.6KF @ 25.9DB LOSS @ 28KHZ
+3.9DB LOSS
S 1725 MEADOWVIEW RD
14KF @ 22.3DB LOSS @ 28KHZ/16.9KF @ 27DB LOSS @ 28KHZ
+4.7DB LOSS
IN 1720 ALEXANDER RD
(T1T-T1R)9KF @ 26.7DB LOSS @ 28KHZ/(HDL2)7KF @ 11.9DB LOSS @ 28KHZ
-14.8DB LOSS
(POTS)14.3KF @ 24.4DB LOSS @ 28 KHZ/17.5KF @ 30DB LOSS @ 28 KHZ
+5.6DB LOSS.
+3DB LOSS.
IN 3103 SIBLEY MEMORIAL HWY
(T1T-T1R)13.5KF @ 23.7DB LOSS @ 28KHZ/(HDL2)6.3KF @ 10.6DB LOSS @ 28KHZ
-13.1DB LOSS.
(POTS)13.5KF @ 23.7DB LOSS @ 28KHZ/15.8KF @ 27.8DB LOSS @ 28KHZ
+4.1DB LOSS
F 3105 SIBLEY MEMORIAL HWY
(T1T-T1R)14.6KF @ 22DB LOSS @ 28KHZ/(HDL2)6.3KF @ 10.5DB LOSS @ 29KHZ
-11.5DB LOSS
(POTS)14.6KF @ 22DB LOSS @ 28KHZ/16.6KF @ 25.9DB LOSS @ 28KHZ
+3.9DB LOSS
S 1725 MEADOWVIEW RD
14KF @ 22.3DB LOSS @ 28KHZ/16.9KF @ 27DB LOSS @ 28KHZ
+4.7DB LOSS
IN 1720 ALEXANDER RD
(T1T-T1R)9KF @ 26.7DB LOSS @ 28KHZ/(HDL2)7KF @ 11.9DB LOSS @ 28KHZ
-14.8DB LOSS
(POTS)14.3KF @ 24.4DB LOSS @ 28 KHZ/17.5KF @ 30DB LOSS @ 28 KHZ
+5.6DB LOSS.
7 STATE MINNESOTA
WIRE CENTER PARK RAPIDS
8-CHARACTER SWITCH ID PKRPMNPR
COMPLETION DATE/PLANNED RETIREMENT DATE 08-07-2006
DA (s) 190202/490402
FDI Address(es) X500/1; X600/22
Replacing DA:190202, 18.4KF FROM CO.
SECTION #1 REPLACE 1000' OF 22GA WITH 24GA AND ALSO ADD 2700' TO END OF LOOP.
SECTION #2:REPLACE 835' OF 22GA WITH 24GA.

DA: 490402, 15.1KF FROM CO.
REPLACE 2654' OF 22GA WITH 24GA.
8 STATE MINNESOTA
WIRE CENTER CHATFIELD
8-CHARACTER SWITCH ID CTFDMNCH
COMPLETION DATE/PLANNED RETIREMENT DATE 07-31-2006
DA (s) 410402, 410302
FDI Address(es) X A6A, X A9A
Replacing THIS IS A PLANNED RETIREMENT DUE TO A HOUSTON COUNTY ROAD PROJECT. THIS IS A SWITCH FROM DIRECT FEED COPPER TO PAIR GAIN. I CAN FIND NO IMPACTED CLEC CIRCUITS. THERE ARE CLEC CIRCUITS IN THIS CABLE, BUT THEY ARE RESALE AND WILL WORK THROUGH THE NEW PG. RETIRING 1459 FEET OF 22 GAUGE 100 PAIR, 12,059 FEET OF 22 GAUGE 75 PAIR, 150 FEET OF 22 GAUGE 25 PAIR AND 10,739 FEET OF 150 PAIR 22 GAUGE. AT X A9A ONLY F2 PAIRS 1-15 ARE AFFECTED.
9 STATE MINNESOTA
WIRE CENTER HINCKLEY
8-CHARACTER SWITCH ID HNCKMNHI
COMPLETION DATE/PLANNED RETIREMENT DATE 06-05-2006
DA (s) 410302
FDI Address(es) X W18-W5M
Replacing THIS JOB WILL REPLACE FOUR MILES OF CABLE THAT WAS WILL BE LOST ON SP# 33-620-08 ALONG KANABEC CSAH 20 IN THE HINCKLEY WIRE CENTER FROM CSAH 3 TO CSAH 5. PLACEMENTS INCLUDE 7,000' OF ANAW-200, 11,345' OF ANAW-50, 5,055' OF ANAW-25, 720' OF 3/22 BSW, 23 SIX PAIR TERMINALS, ONE TEN-INCH CLOSURE, 20 EIGHT-INCH CLOSURES, THIRTEEN SIX-INCH CLOSURES, A 100 PAIR LOAD, A 25 PAIR LOAD, ASSOCIATED PLACING, RESTORAL, BORING AND SPLICING. RETIREMENT OF BURIED PLANT INCLUDES 6,018' OF ALAW-150 (1979), 3,868' OF ALAW-50 (1979), 1,612' OF ANAW-50 (2000), 5,708' OF ALAW-25 (1979), 6,158' OF ALAW-11 (1979), 100-662 LOAD COILS (1979), 25-662 LOAD COILS (1980). DSL IS NOT CURRENTLY AVAILABLE AT DA 410302 OR DA 410402. THE ANAW-200 REPLACES THE ALAW-150 WHICH IS DISTRIBUTION CABLE FOR DA 410302 AND FEEDER CABLE FOR DA 410402.
10 STATE MINNESOTA
WIRE CENTER STEWARTVILLE
8-CHARACTER SWITCH ID STVLMNST
COMPLETION DATE/PLANNED RETIREMENT DATE 05-19-2006
DA (s) 210202
FDI Address(es) 200 2ND AVE SE
Replacing ROAD PROJECT. THIS JOB WILL PLACE 1356 FEET OF ANMW-400. THIS JOB WILL RETIRE 1326 FEET OF EXISTING 400 PAIR 26 GAUGE CABLE. THIS JOB WILL ALSO REPLACE AN EXISTING QWEST-12 PEDESTAL WITH A NEW 1248 PEDESTAL.THE WORK BEGINS AT 2.711 KFT FROM THE STEWARTVILLE CENTRAL OFFICE. THE DB LOSS CALCULATIONS FOR THE INDIVIDUAL COPPER CABLE SECTIONS ARE:BEFORE 1326 FT BHAH-400 @ 28KHZ = 1.40 AFTERV 1356 FEET ANMW-400 @ 28KHZ = 2.14.CHANGE OF +0.74DB.
11 STATE MINNESOTA
WIRE CENTER OWATONNA
8-CHARACTER SWITCH ID OWTNMNOW
COMPLETION DATE/PLANNED RETIREMENT DATE 08-06-2006
DA (s) 221202
FDI Address(es) 221202
Replacing REPLACE 3485' OF 19 GUAGE CABLE WITH 24 3697' OF 24 GUAGE. THE CURRENT DB LOSS AT 28 KHZ =3.350 WITH THE NEW LOSS AT 28KHZ=5.960. NO CLEC SERVICE WILL BE LOST DURING THE JOB. ALL CIRCUITS WILL BE SUPPORTED.
12 STATE MINNESOTA
WIRE CENTER BRAINERD
8-CHARACTER SWITCH ID BRNRMNBR
COMPLETION DATE/PLANNED RETIREMENT DATE 06-22-2006
DA (s) 390402
FDI Address(es) 1520 FORESTVIEW DR S
Replacing THIS AUTHORITY WILL REPLACE A 25 PAIR BURIED CABLE THAT WAS REMOVED DUE TO ROAD CONSTRUCTION. . WORK WILL CONSIST IN PLACING 750 FT OF BURIED ANNM-25 PR CABLE, FIVE 6 PR TERMINAL BLOCKS, SIX 6" CLOSURES AND ASSOCIATED SPLICING
AFTER:
295' OF ANMW-25 @ 196 KHZ=.760750' ANMW-25 @196 KHZ=1.950

CHANGE OF +1.19 DB
13 STATE MINNESOTA
WIRE CENTER ST PETER
8-CHARACTER SWITCH ID STPRMNSP
COMPLETION DATE/PLANNED RETIREMENT DATE 05-30-2006
DA (s) 450202
FDI Address(es) X CSAH 15 & CO RD 63
Replacing THIS JOB WILL PLACE 8820 FEET OF 22 GAUGE 100 PAIR BURIED DISTRIBUTION CABLE, 450 FEET OF 3 PAIR SERVICE WIRE, A 100 PAIR LOAD COIL, 5 PEDESTALS AND 5 PEDESTALS. ABANDONMENTS INCLUDE 17,513 FEET OF 22 GAUGE 50 PAIR BURIED DISTRIBUTION CABLE, 250 FEET OF 19 GAUGE 50 PAIR CABLE AND 2 - 50 PAIR LOAD COILS. THIS WORK BEGINS 45.21 K/FT FROM THE ST PETER CO. THE DB LOSS CALCULATIONS FOR THE INDIVIDUAL COPPER CABLE SECTIONS ARE:

SECTION 1

BEFORE AFTER
8915 FEET OF ALAW-50 AND 250 8760 FEET OF ANAW-100 @ 28KHZ=10.44
FEET OF BHBH-50 @ 28KHZ=10.81
CHANGE OF -.37DB LOSS.

SECTION 2

BEFORE AFTER
8597 FEET OF AFAW-50 @ 28KHZ 8760 FEET OF ANAW-100 @ 28KHZ=10.44DB
=10.24DB
CHANGE OF +.20DB LOSS .
DUE TO A SHORT NOTICE IN THE WORK START DATE FROM NICOLLET COUNTY IT WILL BE NECESSARY TO HAVE A SHORT INTERVAL DISCLOSURE. CUT OVER WILL NEED TO BE PERFORMED IN MAY 2006.THIS REPLACEMENT IS IN ROUTE 4 WEST OF ST PETER. THE DESIGN POINT FROM THE FURTHEST TERMINAL TO THE CO IS 51.56 K/FT WHICH SUPPORTS THE 22 GAUGE CABLE USED TO MAINTAIN SERVICE INTO RZ 28.
14 STATE MINNESOTA
WIRE CENTER CHISHOLM
8-CHARACTER SWITCH ID CHSHMNCS
COMPLETION DATE/PLANNED RETIREMENT DATE 07-07-2006
DA (s) 145505
FDI Address(es) X CO RD 473 & 65
Replacing THIS JOB WILL REPLACE 750' OF 19 & 22 GAUGE CABLE WITH 24 GAUGE. LONGEST LOOP IS 14.8 KILO FEET WITH A MAX. LOOP RESISTANCE OF 488 OHMS. EXCEPTION TO THE 95 DAY RULE REQUESTED TO TO COUNTY BRIDGE REPLACEMENT.
15 STATE MONTANA
WIRE CENTER BOZEMAN
8-CHARACTER SWITCH ID BZMNMTMA
COMPLETION DATE/PLANNED RETIREMENT DATE 06-30-2006
DA (s) 113121
FDI Address(es) X 501 BOND
Replacing JOB 624C745 IS CABLING WITHIN AN EXISTING OLD WAREHOUSE AREA THAT IS HAVING A MAKE-OVER AT THE NW CORNER OF E OAK ST AND N ROUSE AVE. AN EXISTING ENTRANCE CABLE AND PROTECTOR ARE BEING REMOVED TO ONE OF THE BUILDINGS CURRENTLY BEING DEMOLISHED. THE CABLE WILL NOT BE REPLACED. NO IMPACT TO ANY CIRCUITS OR CUSTOMERS.
BEFORE AFTER
9.69KF @ 28KHZ = 20.85DB NO REPLACEMENT CABLE DUE TO DEMOLITION
16 STATE MONTANA
WIRE CENTER BOZEMAN
8-CHARACTER SWITCH ID BZMNMTMA
COMPLETION DATE/PLANNED RETIREMENT DATE 05-19-2006
DA (s) 460111/417525
FDI Address(es) X 2301 WEST OAK/X/2 N 24 AV
Replacing QWEST IS REMOVING 1447 FT AERIAL COPPER LEAD IN CONFLICT WITH ROAD WIDENING PROJECT ON DURSTON RD. OLD COPPER FACILITY IS REMOTE TERMINAL FEED AT X 2301 WEST OAK. ALL EXISTING SERVICES WILL BE SUPPORTED BY ANOTHER DA, X 2 N 24 AV (F1-26 GUAGE=6.787 KFT, F1-24 GUAGE=1.782 KFT, F2-24 GUAGE=4.610 KFT.
17 STATE MONTANA
WIRE CENTER BILLINGS WEST
8-CHARACTER SWITCH ID BLNGMTWE
COMPLETION DATE/PLANNED RETIREMENT DATE 06-15-2006
DA (s) 310261
FDI Address(es) NA
Replacing THE WORK BEGINS AT 11.5 KFT FROM THE BILLINGS WEST CENTRAL OFFICE. THE DB LOSS CALCULATIONS FOR THE INDIVIDUAL COPPER CABLE SECTIONS ARE:

BEFORE:1300'BHBA-50@28KHZ=.770
AFTER: 1340'BHBA-50@28KHZ=.790
BEFORE:1458'BHBH-400@28KHZ=.870
AFTER: 1458'BHBH-400@28KHZ+
40'ANAW-400@28KHZ=.910
BEFORE: 49'ALMW-25@28KHZ=.080
AFTER: 80'ALMW-25@28KHZ=.140
BEFORE: 644'AJMW-25@28KHZ=1.050
AFTER: 684'AJMW-25@28KHZ=1.110
BEFORE: 300'AFMW-600@28KHZ=.500
AFTER: 320'AFMW-600@28KHZ=.530
BEFORE:1380'ANMW-600@28KHZ=2.170
AFTER: 1420'ANMW-600@28KHZ=2.230
BEFORE: 916'ALMW-600@28KHZ=1.470
AFTER: 956'ALMW-600@28KHZ=1.530

ALL SECTIONS CHANGE +.02DB TO +.06DB - LOSS REQUIRES NOTIFICATION DISCLOSURE.
18 STATE NEW MEXICO
WIRE CENTER ALAMOGORDO MAIN
8-CHARACTER SWITCH ID ALMGNMMA
COMPLETION DATE/PLANNED RETIREMENT DATE 05-30-2006
DA (s) 310801
FDI Address(es) X 701 E 1
Replacing JOB WILL ABANDON 313' OF ALTW-100 CABLE DUE TO DEMOLITION OF BUILDING, NEW BUILDING WILL BE SERVED OUT OF A DIFFERENT SAI. ABADONMENT OF CABLE DOES NOT NEGATIVELY AFFECT THE LOOP MAKE UP
19 STATE NEW MEXICO
WIRE CENTER ALBUQUERQUE SOUTHWEST
8-CHARACTER SWITCH ID ALBQNMSW
COMPLETION DATE/PLANNED RETIREMENT DATE 04-28-2006
DA (s) 411201
FDI Address(es) X 4301 COORS BLVD SW
Replacing RELOCATE FACILITIES AT INTERSECTION OF COORS & GUN CLUB FOR ROAD PROJECT.
THIS WORK ENTAILS PLACMENT OF MULTIPLE STUBS IN ORDER TO RELOCATE A MAJOR BRANCH SPLICE OUT OF THE WAY OF A NEW TURN LANE.
IN ADDITION SEVERAL AERIAL TRANSFERS TO NEW POWER COMPANY POLES WILL BE NECESSARY.A 198' LENGTH OF ANMW-300 IS BEING REPLACED WITH 165' OF ANMW-400 AND 42' OF ANMW-900. A 20' 10B2-200 STUB IS BEING ABANDONED AND REPLACED WITH
A 42' ANMW-900 AND A 50' ANMW-100.
WORK BEGINS AT 15.921KF FROM THE SOUTHWEST CENTRAL OFFICE.
THE DB LOSS FOR THE INDIVIDUAL COPPER CABLE SECTIONS ARE:
BEFORE AFTER
198' ANMW-300 @ 28KHZ = 0.370 165' ANMW-400+ 42' ANMW-900 @ 28 KHZ = 0.390
CHANGE OF +0.020 DB LOSS
20' 10B2-200 @ 28KHZ = 0.040 42' ANMW-900+ 50' ANMW-100 @ 28 KHZ = 0.170
CHANGE OF +0.130 DB LOSS.
20 STATE OREGON
WIRE CENTER WOODBURN
8-CHARACTER SWITCH ID WDBNOR59
COMPLETION DATE/PLANNED RETIREMENT DATE 08-25-2006
DA (s) 420701
FDI Address(es) X 8099 STATE HIGHWAY 214 & X 16235 BUTTEVILLE RD NE
Replacing QWEST IS REMOVING TWO INTERFACE TERMINALS AT 8099 STATE HIGHWAY 214 AND 16235 BUTTEVILLE RD NE. THESE WILL BE REPLACED WITH A NEW SAI AT 16236 BUTTEVILLE RD WHICH IS LOCATING 552' AND 290' FROM THE EXISTING SAI'S.
COPPER RETIREMENTS AND REPLACEMENTS:
134' 24 GA REPLACES WITH 602' 24GA CURRENT DB LOSS= .230 NEW DB LOSS= .980
304' 24GA REPLACES WITH 864' 24GA CURRENT DB LOSS= .510 NEW DB LOSS= 1.390

EXISTING F-2 COUNTS WILL BE CUT INTO THE F-2 FROM 16236 BUTTEVILLE RD.
CHANGE OF .75 DB LOSS AT F-2 16235B
CHANGE OF .88 DB LOSS AT F-2 8099S
21 STATE OREGON
WIRE CENTER EUGENE
8-CHARACTER SWITCH ID EUGNOR53
COMPLETION DATE/PLANNED RETIREMENT DATE 07-24-2006
DA (s) 415908
FDI Address(es) X-3340 W 18TH AVE
Replacing THIS EWO PROPOSES REPLACING AN AERIAL LEAD CABLE BETWEEN T-1840 TO T-2098 TODD STREET LOCATED SOUTHWEST OF THE EUGENE CENTRAL OFFICE.THIS JOB PLACES 1170' OF 100 X 24 GA AERIAL CABLE AND REMOVES 1044' OF 50 X 22 GA AERIAL LEAD CABLE.
BEFORE AFTER
1044' OF 51X22 GA LEAD @ 28KHZ = 1.1 1170' OF BKMP-100 @ 28KHZ = 1.86
CHANGE OF +.176 DB LOSS.
22 STATE UTAH
WIRE CENTER SALT LAKE CITY SOUTH
8-CHARACTER SWITCH ID SLKCUTSO
COMPLETION DATE/PLANNED RETIREMENT DATE 05-31-2006
DA (s) 411502
FDI Address(es) X-3044 S WEST TEMPLE
Replacing RELOCATE EXISTING AERIAL CABLE TO BURIED, IN THE WAY OF NEW DAL TILE BUILDING. CHANGE IN TRANSMISSION PROPERTIES AS FOLLOWS:.
BEFORE: 700' OF 24 GAUGE - 28KHZ= 3.430
AFTER: 882' OF 24 GAUGE) CABLE- 28KHZ= 3.590
RETIREMENT CANNOT WAIT THE 95 DAYS DUE TO CUSTOMER CONSTRUCTION,
EXISTING CABLE IN THE WAY OF NEW BUILDING..
23 STATE WASHINGTON
WIRE CENTER SEATTLE EAST
8-CHARACTER SWITCH ID STTLWA03
COMPLETION DATE/PLANNED RETIREMENT DATE 05-26-2006
DA (s) 494102
FDI Address(es) X 1301 31ST ST
Replacing ON S JUDKINS AT 33D S, JOB WILL REPLACE 134' OF 22GA(0.15 DB @ 40 KHZ) AERIAL CABLE WITH 195' OF 24GA(0.33 DB @ 40 KHZ) UNDERGROUND CABLE. THIS WORK WILL ADD A TOTAL OF 0.18 DB @ 40 KHZ. . THIS JOB AFFECTS TERMINALS 1117 LAKE WASHINGTON BV, 1101 LAKE WASHINGTON BV, 1314 LAKE WASHINGTON BV, 3401 S JUDKINS.
24 STATE WASHINGTON
WIRE CENTER NORTHPORT
8-CHARACTER SWITCH ID NPRTWA01
COMPLETION DATE/PLANNED RETIREMENT DATE 05-30-2006
DA (s) 3109 AND 3113
FDI Address(es) X 3200 ALDDIN RD AND X 2594 ALADDIN RD
Replacing DA 3109 WILL REPLACE 6375' OF 22GA WITH 6510' OF 22G, INCREASING THE DB BY .04 @1004KHZ FROM 2.56 TO 2.60
DA 3113 WILL REPLACE 6925' OF 22 GA. WITH 7064' OF 22GA, INCREASING THE DB BY .04 @1004KHZ FROM 2.95 TO 2.99. COUNTY ROAD PROJECT REQUIRES IMMEDIATE RETIREMENTS. NO CLEC CIRCUITS AFFECTED.
25 STATE WASHINGTON
WIRE CENTER PASCO
8-CHARACTER SWITCH ID PACSWA01
COMPLETION DATE/PLANNED RETIREMENT DATE 08-24-2006
DA (s) 432803
FDI Address(es) F1
Replacing QWEST IS REMOVING LEAD CABLE ON S 20TH AVENUE. THIS CABLE IS CURRENTY STRAIGHT UNDERGROUND COUNT AND IS 1.353 KFT OF 24 GAUGE AND 7.581 KFT OF 26GAUGE. IT WILL BE CUT TO A NEW SAI WITH 9.852 KFT OF 26 GAUGE F1 AND 2.854 KFT OF 26 GAUGE F2. THE OLD F1/F2 LOOP LENGTH WAS 8.93 KFT AND THE NEW F1/F2 LOOP WILL BE 13.677 KFT. THE NEW SAI WILL SUPPORT CO BASED DSL.
Additional Information:

Any customer premises equipment vendor/manufacturer or enhanced services provider desiring additional technical information in conjunction with this Disclosure can contact:

Georganne Weidenbach
Georganne.Weidenbach@qwest.com

This Network Disclosure is available as a PDF download (file size: 112Kb). If you need to print Network Disclosures, the PDF file will give you more flexibility and a higher quality printout than will a Web page, which is designed to be viewed with a Web browser. If you need the Adobe Reader, you can download it for free from Adobe's Web site.

Back to Top - Net Disclosure Main Page
Net Disclosures Listed Numerically

Questions regarding Network Disclosure information can be referred to the individual listed on the Disclosure Announcement or e-mail Dean Martineau, Qwest's Manager of Network Disclosures at a.martineau@qwest.com.